8
8555-9201-000
/
0109
Mechanical Separation /
GEA Westfalia Separator
1.1
Timer list OSD 6-...-…
Tim
er
Control D10
Remarks
Separator model
Complete text
Display text
OSD 6
-0136-
-0196-
-91-
HFO
LO
LO / (M)DO / HFO
sec
T00
Partial ejection
Partial ejection
1.5
1.5
1.5
T01
Displacement
Displacement
8
8
8
T02
Filling
Filling
8
8
8
T03
Waiting
Waiting
5
5
5
T04
Total ejection
Total ejection
2
2
2
T05
Speed recovery after total ejection
Speed recov. total
8
8
8
T06
Closing water impulse
Closingwater imp
0.08
0.08
0.08
T07
Alarm delay
Alarm delay
10
10
10
T08
Waiting after displacement
Wait aft.displac
5
5
5
T09
Waiting after filling
Wait aft.filling
5
5
5
T10
Separator starting
Sep. runup
240
240
240
T11
Alarm bridging
Alarm-bridging
30
30
30
T12
Waiting after 1st ejection
Wait aft 1. Eject
5
5
5
T13
Speed recovery after partial ejection
Speed rec.part Speed
8
8
8
T14
Closing water interval
Closing Interval
600
600
600
T15
Circulation valve close
Circ.valve clos
60
0
0
T16
Circulation valve open
Circ.valve open
5
0
0
T17
Water content bridging
Water cont. bridging
0
600
0
T18
Sludge tank alarm delay
LSHH-Sludgetank
10
10
10
T19
Water impulse at start
Water pulse bef. start
3
3
3
T20
Separation
Separation
no password
7 200
7 200
7 200
T21
Min. separation time
Min-Sep.-Time
600
0
0
T22
High water content
High water cont.
10
10
0
T23
Feed pump delay
Feed pump delay
300
300
300
T24
Sludge pump delay off
Sludgep.delay
60
60
60
T25
Vibration 1 - delay
Vibro 1
option
180
180
180
T26
Vibration 2 -delay
Vibro 2
option
2
2
2
T27
SMS low pressure delay
SMS PSL delay
10
0
0
T28
Ejection monitoring
Ejection monitor
5
5
5
T29
Brake for separator
Brake for Sep.
option
300
300
300
T30
Free
Free
T31
Free
Free
T32
WMS-Mode
WMS-Mode
0
5 400
0
T33
SMS-Mode
SMS-Mode
0
120
0
T34
Circuit valve delay
Circuirt v. delay
0
10
0
T35
Water seal broken
Water.Seal
0
10
0
T36
SMS Press.Check
SMS Press.Check
0
1
0
T37
SMS Waiting
SMS Waiting
0
3
0
T38
WMS sensor flushing
WMS sens. flushing
0
20
0
T39
Separator motor off
Separator off
1 800
1 800
1 800
T40
CU sludge pump on
CE sludgepump on
option
60
60
60
T41
CU sludge pump delay
CU-Sl.Pu delay
option
600
600
600
T42
Free
Free
-
-
-
T43
Free
Free
-
-
-
T44
SMS sensor check
SMS sensor check
option
35
35
0
T45
WMS sensor check
WMS sensor check
option
300
20
0
T46
Free
Free
-
-
-
T47
Min.SMS Time
Min. SMS Time
0
18
0
T60
Start impulse
Start impulse
option
10
10
0
T61
Sensor interval
Sensor interval
option
2
2
0
T62
Sensor impulse
Sensor impulse
option
1
1
0