8555-9201-000
/
0109
53
Mechanical Separation /
GEA Westfalia Separator
4.8
Alarm #10 - Sludge pump fault
SLUDGE PUMP FAULT
Program stop
Alarm#10 ENTER
Text display
Possible causes
Action
Sludge pump overloaded.
•
Check protective switch and current
consumption.
Sludge pump mechanically blocked.
•
Check pump.
Valve in the pressure line closed.
•
Check valves.
Pipe on the suction and pressure side
of the pump blocked.
•
Check pipes.
Electrical connections incorrect.
•
Check electrical connections and
wiring.
Help text – information on the control system
E N T E R
Step 1
Acknowledge fault
H E L P
Step 2
Press key >F1<
Help on alarm
Key >HOME<back
Page 1
SLUDGE PUMP FAULT
Please check:
Protective switch
Current consumption
->
Page 2
Pump
Valves
Pipes
Electr. connections
->
Page 3
Wiring
back with ENTER
F 1