Mechanical Separation /
GEA Westfalia Separator
4.12 Alarm #15 - WMS system fault
WMS – SYSTEM FAULT
Too much water
Separation “Stop”
Alarm#15 ENTER
Text display
Possible causes
Action
Water content in feed too high.
•
Check product feed.
Too much filling water.
T02 set too long.
•
Check T02.
Filling water valve V2 leaks.
•
Check filling water valve V2.
Incorrect setting on evaluating relay.
•
Check setting on evaluating relay.
T22 set too short.
•
Check setting T22.
•
If necessary, extend T22 during this
phase.