58
8555-9201-000
/
0109
Mechanical Separation /
GEA Westfalia Separator
4.13 Alarm #18 - Bowl monitoring
BOWL MONITORING
Current too high
during TIMER 06
Alarm#18 ENTER
Text display
Possible causes
Action
Closing water pulse T06 too long,
bowl has opened.
•
Check T06.
Water pressure for hydraulics during
T06 too high, bowl has opened.
•
Check water pressure with open
valve V3.
Valve V3 is soiled, catches, remains
open too long.
•
Check valve V3.
New clutch shoes fitted.
•
Check current value.
New belt fitted.
•
Check current value.
•
Deselect function if required.
Help text – information on the control system
E N T E R
Step 1
Acknowledge fault
H E L P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
BOWL MONITORING
Please check:
Timer 06
Water pressure for hydraulics
->
Page 2
Function V3
Current value
->
Page 3
back with ENTER
F 1