8555-9201-000
/
0109
65
Mechanical Separation /
GEA Westfalia Separator
4.20 Alarm #33 - Ejection monitoring (option)
EJECTION MONITITORING
Eject. speed < offset
Separation “Stop”
Alarm#33 ENTER
Text display
Possible causes
Action
Operating water valve V3 does not
open.
•
Check bowl hydraulic function with
valve V3.
Connector on valve V3 loose.
•
Check connector on V3.
Offset for ejection speed adjusted too
high.
•
Check offset setting.
Water volume at V3 too low.
•
Check water volume.
Monitoring time T28 set too short.
•
Check T28.
Speed pickup defective.
•
Check speed pickup electrically;
replace if necessary.
Filter insert in strainer at solenoid
block soiled.
•
Check filter insert.
Clutch shoes worn or oily.
•
Check clutch shoes.
Note:
Alarm #33 only active when speed pickup is installed!
Help text – information on the control system
E N T E R
Step 1
Acknowledge fault
H E L P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
EJECTION MONITORING
Please check:
Function bowl
hydraulics with V3
->
Page 2
Connector valve V3
Speed< offset
Water volume
T28
->
Page 3
Speed pickup
electric
Pre-strainer
back with ENTER