4.16 Alarm #22 - Sludge pump running time too long
SLUDGE PUMP RUNNING
TIME TOO LONG
In TR3 hours
Alarm#22 ENTER
Text display
Possible causes
Action
Time recording TT2 set too short.
•
Check time recording TR2.
Bowl leakage
•
Check bowl function/hydraulics.
Water content in feed too high.
•
Dewater product upstream of sepa-
rator.
Slight product overflow due to clean
oil discharge pressure set too high.
•
Check clean oil discharge setting.
Sludge pump output too low.
•
Check pump function.
Note:
TR2 = Sludge pump time.
TR3 = Time recording zero position. Factory setting 24h.
Help text – information on the control system
E N T E R
Step 1
Acknowledge fault
H E L P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
SLUDGE PUMP RUNNING
TIME TOO LONG
Please check:
TR2 time recording
->
Page 2
Bowl function
Bowl leakage
Water content in
product
->
Page 3
Pump function
back with ENTER
F 1