48
8555-9201-000
/
0109
Mechanical Separation /
GEA Westfalia Separator
4.3
Alarm #05 - TAL product feed
TAL product feed
Temp.< min
Separation “Stop”
Alarm#05 ENTER
Text display
Possible causes
Action
Product too cold before preheater
•
Check settling tank temperature.
Feed capacity too high.
•
Check feed capacity.
Setpoint TAL set too high.
•
Check setpoint TAL.
Temperature of heating medium too
low.
•
Check heating medium tempera-
ture.
Temperature controller defective.
•
Check temperature controller.
Controller setting or function not o.k.
•
Check controller setting and func-
tion.
Line compensation at controller not
correctly adjusted.
•
Check line compensation at con-
troller.
Preheater soiled.
•
Check preheater.
PT 100 sensor defective.
•
Check sensor.
Help text on the control system
E N T E R
Step 1
Acknowledge fault
H E L P
Step 2
Press key >F1<
Help on alarm
Press key >HOME< back
Page 1
PRODUCT TEMP.- MIN
Please check:
Settling tank temperature
Feed capacity
->
Page 2
Setpoint TAL
Temp. heating medium
Temp. controller
Switching stages elect.
->
Page 3
Preheater
PT100 sensor
Back with ENTER
F 1