Mechanical Separation /
GEA Westfalia Separator
4.32 Alarm #45 - PAH1 clean oil discharge
PAH1 – CLEAN OIL
DISCHARGE
Pressure >3.0 bar
Separation “Stop”
Alarm#45 ENTER
Text display
Possible causes
Action
Clean oil discharge valve (product
discharge valve) V7 closed too far.
•
Check valve position V7.
Feed capacity too high.
•
Check feed capacity.
Setpoint at pressure transmitter PT1
set too low.
•
Check setpoint at pressure transmit-
ter PT1.
Alarm delay T07 too short.
•
Check T07.
Alarm bridging T11 too short.
•
Check T11.
Product temperature too low.
•
Check temperature in product feed.
Help text – information on the control
E N T E R
Step 1
Acknowledge fault
H E L P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
PRESSURE INCREASE
CLEAN OIL
Please check
Ventilstellung V7
Z l fl i t
->
Page 2
Setpoint PT1
T07 alarm delay
T11 alarm bridging
Temp. product feed
->
Page 3
Filling water volume
Bowl leakage
T07 Alarm delay
Back with ENTER
F 1