8555-9201-000
/
0109
11
Mechanical Separation /
GEA Westfalia Separator
1.4
Timer list OSD 60-...-…
Ti
m
er
Control D10
Remarks
Separator model
Complete text
Dis play text
OSD 60
-0136-
-0196-
-91-
HFO
LO
LO / (M)DO / HFO
s ec
T00
Partial ejection
Partial ejection
3
3
3
T01
Displacement
Displacement
100
100
100
T02
Filling
Filling
100
100
100
T03
Waiting
Waiting
5
5
5
T04
Total ejection
Total ejection
3.5
3.5
3.5
T05
Speed recovery after total ejection
Speed recov. total
20
20
20
T06
Closing water impulse
Closingwater imp
0.1
0.1
0.1
T07
Alarm delay
Alarm delay
10
10
10
T08
Waiting after displacement
Wait aft.displac
5
5
5
T09
Waiting after filling
Wait aft.filling
5
5
5
T10
Separator starting
Sep. runup
600
600
600
T11
Alarm bridging
Alarm-bridging
30
30
30
T12
Waiting after 1st ejection
Wait aft 1. Eject
5
5
5
T13
Speed recovery after partial ejection
Speed rec.part Speed
20
20
20
T14
Closing water interval
Closing Interval
600
600
600
T15
Circulation valve close
Circ.valve clos
60
0
0
T16
Circulation valve open
Circ.valve open
5
0
0
T17
Water content bridging
Water cont. bridging
0
600
0
T18
Sludge tank alarm delay
LSHH-Sludgetank
10
10
10
T19
Water impulse at start
Water pulse bef. start
3
3
3
T20
Separation
Separation
no password
7 200
7 200
7 200
T21
Min. separation time
Min-Sep.-Time
600
0
0
T22
High water content
High water cont.
30
30
0
T23
Feed pump delay
Feed pump delay
300
300
300
T24
Sludge pump delay off
Sludgep.delay
100
100
100
T25
Vibration 1 - delay
Vibro 1
option
180
180
180
T26
Vibration 2 -delay
Vibro 2
option
2
2
2
T27
SMS low pressure delay
SMS PSL delay
10
0
0
T28
Ejection monitoring
Ejection monitor
5
5
5
T29
Brake for separator
Brake for Sep.
option
1 200
1 200
1 200
T30
Free
Free
T31
Free
Free
T32
WMS-Mode
WMS-Mode
0
5400
0
T33
SMS-Mode
SMS-Mode
0
120
0
T34
Circuit valve delay
Circuirt v. delay
0
10
0
T35
Water seal broken
Water.Seal
0
10
0
T36
SMS Press.Check
SMS Press.Check
0
2
0
T37
SMS Waiting
SMS Waiting
0
3
0
T38
WMS sensor flushing
WMS sens. flushing
0
20
0
T39
Separator motor off
Separator off
1 800
1 800
1 800
T40
CU sludge pump on
CE sludgepump on
option
60
60
60
T41
CU sludge pump delay
CU-Sl.Pu delay
option
600
600
600
T42
Free
Free
-
-
-
T43
Free
Free
0
0
0
T44
SMS sensor check
SMS sensor check
option
260
260
0
T45
WMS sensor check
WMS sensor check
option
300
20
0
T46
Free
Free
-
-
-
T47
Min.SMS Time
Min. SMS Time
0
5
0
T60
Start impulse
Start impulse
option
140
140
0
T61
Sensor interval
Sensor interval
option
2
2
0
T62
Sensor impulse
Sensor impulse
option
1
1
0