Operation and control
Operation / Control
7159-9001-108
01. February 2020
Automatic mode
Manual interventions are not necessary in automatic mode.
Note:
Switch ”2” must be in the central position in automatic mode.
Manual mode
Switch on manual mode
1. Operate the switch. (3 - MAN)
- Entrance gate closes
- Segregation gates close
AUTO
MAN
- LED lights up
For display in the user interface see corresponding section.
Manual mode (VP1801) = LED I4
For more information, see: 7160-90 . . -427
Open entrance gate
1. Operate the switch. (1)
- Entrance gate opens
Close entrance gate
1. Operate the switch. (1)
- Entrance gate closes
Open/close segregation gate
2. Switch in centre position - Segregation gates closed.
A
B
3. Operate the switch. (2)
- Segregation gate opens (SG B)
- Segregation gate closes (SG A)
A
B
4. Operate the switch. (2)
- Segregation gate opens (SG A)
- Segregation gate closes (SG B)
A
B
Switch on automatic mode
1. Operate the switch. (3 - AUTO)
- Entrance gate opens
- Segregation gates close
AUTO
MAN
- Display disappears
Manual mode (VP1801) = LED I4