commissioning
Settings in DairyPlan
7159-9001-108
01. February 2020
Setting the segregation methods (E)
1. Click on ”Segregation method setup” to call up the corresponding setup menu.
G
Selection Method
J
H2
H3
A
2
3
4
5
6
B
C
D
1
H1
G
Selecting the segregation path
Setting according to segregation path
H1
Selection of segregation methods
Depending on the segregation path, up to 6 segregation methods can be set.
See table ”Segregation methods”
Note:
Segregation methods are requested for each segregation path (starting with A, then B, …
) in the order set (1-6).
Make sure that the segregation methods for different segregation paths are not mutually
exclusive!
H2
Supplementary setting for segregation method
Examples:
● Segregation method: 1 (2)
Individual animal selection flags
Animals are only segregated if their individual selection flags correspond with the
selection flags set here.
Note:
A selection flag must always be set for segregation methods 1 and 2!
If no selection flag is set the segregation method will work with selection flag 1.
● Segregation method: 3
Group ID number
H3
Start time / End time
(timeframe)
The various segregation methods can each be given a start and end time.
J
Animal counter for areas
Which animals were separated in which segregation passageway.
2. Enter the settings specified (G-J)
3. Set individual animal selection flags if necessary
For further information, please refer to:
Setting selections flags (DPSingle)