6. Control Functions and Parameter Settings
6-71
The signal conversion circuit is according the following combination.
Setting
No.
A-IN
forward/
reverse
B-IN
forward/
reverse
Z-IN
forward/
reverse
AB
inter-
change
0
-
-
-
1
Reverse
-
-
2
-
Reverse
-
3
Reverse
Reverse
-
4
-
-
Reverse
5
Reverse
-
Reverse
6
-
Reverse
Reverse
7
Reverse
Reverse
Reverse
No inter-
change
8
-
-
-
9
Reverse
-
-
10
-
Reverse
-
11
Reverse
Reverse
-
12
-
-
Reverse
13
Reverse
-
Reverse
14
-
Reverse
Reverse
15
Reverse
Reverse
Reverse
AB inter-
change
C51-0
Encoder UVW pulse type selection for Permanent Magnet motor (PM)
A position encoder which outputs a 3ph 180º square wave is used for permanent magnet
motors. Check PCST3301 manual of optional U2KV23DN3 PM encoder card.