L60 Line Phase Comparison System
GE Multilin
2.1 INTRODUCTION
2 PRODUCT DESCRIPTION
2
2.1.2 ORDERING
The L60 is available as a 19-inch rack horizontal mount unit or a reduced size (¾) vertical mount unit, and consists of the
following modules: CPU, faceplate, power supply, CPU, CTs and VTs, digital input and outputs, transducer inputs and out-
puts, and inter-relay communications. Each of these modules can be supplied in a number of configurations specified at the
time of ordering. The information required to completely specify the relay is provided in the following tables (see chapter 3
for additional details of relay modules).
The L60 is specified with two CT/VT modules (8F and 8P). When the L60 is applied in two-breaker configurations (such as
breaker-and-a-half or ring configurations), the currents from the two CTs are summed internally within the relay or exter-
nally. If the voltage is not supplies to the relay, some functions (such as distance, undervoltage, and synchrocheck) will not
be available.
Order codes are subject to change without notice. Refer to the GE Multilin ordering page at
http://www.GEindustrial.com/multilin/order.htm
for the latest details concerning L60 ordering options.
The order codes for the horizontal mount units are shown below.
Table 2–2: OTHER DEVICE FUNCTIONS
FUNCTION
FUNCTION
Breaker Arcing Current (I
2
t)
IEC 61850 Communications (optional)
Breaker Control
Modbus Communications
Contact Inputs (up to 96)
Modbus User Map
Contact Outputs (up to 64)
Non-Volatile Latches
Control Pushbuttons
Non-Volatile Selector Switch
CT Failure Detector
Open Breaker Echo
Data Logger
Oscillography
Digital Counters (8)
Pilot Scheme (POTT)
Digital Elements (48)
Setting Groups (6)
Disconnect Switches
Time Synchronization over SNTP
DNP 3.0 or IEC 60870-5-104 Communications
Transducer Inputs/Outputs
Event Recorder
Trip Bus
Fault Location
User Definable Display
Fault Reporting
User Programmable LEDs
FlexElements™ (8)
User Programmable Pushbuttons
FlexLogic™ Equations
User Programmable Self-Tests
Line Pickup
Virtual Inputs (64)
Load Encroachment
Virtual Outputs (96)
Metering:
Current, Voltage, Power, Frequency
VT Fuse Failure
NOTE
Содержание UR series
Страница 2: ......
Страница 4: ......
Страница 12: ...xii L60 Line Phase Comparison System GE Multilin TABLE OF CONTENTS ...
Страница 32: ...1 20 L60 Line Phase Comparison System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 54: ...2 22 L60 Line Phase Comparison System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Страница 132: ...4 30 L60 Line Phase Comparison System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 438: ...7 8 L60 Line Phase Comparison System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 478: ...8 40 L60 Line Phase Comparison System GE Multilin 8 3 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Страница 502: ...A 10 L60 Line Phase Comparison System GE Multilin A 1 PARAMETER LIST APPENDIXA A ...
Страница 584: ...B 82 L60 Line Phase Comparison System GE Multilin B 4 MEMORY MAPPING APPENDIXB B ...
Страница 622: ...D 10 L60 Line Phase Comparison System GE Multilin D 1 PROTOCOL APPENDIXD D ...
Страница 634: ...E 12 L60 Line Phase Comparison System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Страница 642: ...F 8 L60 Line Phase Comparison System GE Multilin F 3 WARRANTY APPENDIXF F ...