489 GENERATOR MANAGEMENT RELAY – COMMUNICATIONS GUIDE
57
CG.4.2 Implementation Table
The table below gives a list of all objects recognized and returned by the relay. Additional
information is provided on the following pages including a list of the default variations
returned for each object and lists of defined point numbers for each object.
Implementation Table Notes:
1.
For this object, the quantity specified in the request must be exactly 1 as there is only
one instance of this object defined in the relay.
2.
All static data known to the relay is returned in response to a request for Class 0. This
includes all objects of type 1 (Binary Input), type 10 (Binary Output), type 20 (Binary
Counter), type 21 (Frozen Counter) and type 30 (Analog Input).
Executes Control Operations:
Write Binary Outputs
Never
Always
Sometimes
Configurable
Select/Operate
Never
Always
Sometimes
Configurable
Direct Operate
Never
Always
Sometimes
Configurable
Direct Operate: No Ack
Never
Always
Sometimes
Configurable
Count > 1
Never
Always
Sometimes
Configurable
Pulse On
Never
Always
Sometimes
Configurable
Pulse Off
Never
Always
Sometimes
Configurable
Latch On
Never
Always
Sometimes
Configurable
Latch Off
Never
Always
Sometimes
Configurable
See
Binary / Control Relay Output Block (Objects 10/12)
on page CG–64 for an
explanation of the above.
Queue
Never
Always
Sometimes
Configurable
Clear Queue
Never
Always
Sometimes
Configurable
Reports Binary Input Change Events when
no specific variations requested:
Never
Only time-tagged
Only non-time-tagged
Configurable to send both, one or the
other
Reports time-tagged Binary Input Change
Events when no specific variation
requested:
Never
Binary Input Change With Time
Binary Input Change With Relative
Time
Configurable
Sends Unsolicited Responses:
Never
Configurable
Only certain objects
Sometimes
ENABLE/DISABLE UNSOLICITED
Function codes supported
Sends Static Data in Unsolicited
Responses:
Never
When Device Restarts
When Status Flags Change
Default Counter Object/Variation:
No Counters Reported
Configurable
Default Object / Default Variation
Point-by-point list attached
Counters Roll Over at:
No Counters Reported
Configurable
16 Bits
32 Bits
Other Value
Point-by-point list attached
Sends Multi-Fragment Responses:
Yes
No
DNP 3.0: DEVICE PROFILE DOCUMENT (Continued)
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Содержание Multilin 489
Страница 2: ......
Страница 4: ...CGTOC II 489 GENERATOR MANAGEMENT RELAY COMMUNICATIONS GUIDE TABLE OF CONTENTS...