CHAPTER 2: INSTALL ATION/CONFIGURATION
2.86
EP OS MOTOR MANAGEMENT SYSTEM – INSTRUCTION MANUAL
Motor Starter Standard Configuration
EntelliPro ES5
Full-voltage
non-
reversing
Full-voltage
reversing
Star-delta
non-
reversing
Star-delta
reversing
Softstarter
Softstarter
reversing
Breaker
Dahlander
Polechanger
Actuator
Solenoid
Valve
Input 97 Mapping
Reset Alarm
Reset Alarm
Delta
Contactor
Feedback
Y Contactor
Feedback
Reset Alarm
Bypass
Contactor
Feedback
Breaker
Charged
Contactor Y
Feedback
Reset Alarm
External
Supervision
Drawer
Position Test
Input 97 High/low Activation
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Input 96 Mapping
Drawer
Position Test
Drawer
Position Test
Drawer
Position Test
Delta
Contactor
Feedback
Up to Speed
Feedback
Up to Speed
Feedback
Tripped
Drawer
Position Test
Drawer
Position Test
Mode Switch
Local
Mode Switch
Local
Input 96 High/low Activation
Active High
Active High
Active High
Active High
Active High
Active High
Active Low
Active High
Active High
Active High
Active High
Input 95 Mapping
Drawer
Position
Operation
Drawer
Position
Operation
Drawer
Position
Operation
Reset Alarm
fb starter
fault
fb starter
fault
Tripped 2
Drawer
Position
Operation
Drawer
Position
Operation
Mode Switch
Remote
Mode Switch
Remote
Input 95 High/low Activation
Active High
Active High
Active High
Active High
Active Low
Active Low
Active Low
Active High
Active High
Active High
Active High
Input 94 Mapping
Main Circuit
Feedback
Main Circuit
Feedback
Main Circuit
Feedback
Main Circuit
Feedback
Main Circuit
Feedback
Main Circuit
Feedback
Main Circuit
Feedback
Main Circuit
Feedback
Main Circuit
Feedback
Main Circuit
Feedback
Main Circuit
Feedback
Input 94 High/low Activation
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Input 93 Mapping
Control
Circuit
Feedback
Control
Circuit
Feedback
Control
Circuit
Feedback
Control
Circuit
Feedback
Control
Circuit
Feedback
Control
Circuit
Feedback
Control
Circuit
Feedback
Control
Circuit
Feedback
Control
Circuit
Feedback
Control
Circuit
Feedback
Control
Circuit
Feedback
Input 93 High/low Activation
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Input 11 Mapping
Cmd OFF
Cmd OFF
Cmd OFF
Cmd OFF
Cmd OFF
Cmd OFF
Cmd OFF
Cmd OFF
Cmd OFF
Cmd OFF
cmd close
Input 11 High/low Activation
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Input 12 Mapping
Cmd ON
Cmd ON
Right
Cmd ON
Cmd ON
Right
Cmd ON
Cmd ON
Right
Cmd ON
Cmd ON
slow
Cmd ON
slow
Cmd ON
Right
cmd open
Input 12 High/low Activation
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Input 13 Mapping
Not Used
Cmd ON
Reverse
Reset Alarm
Cmd ON Left
Drawer
position Test
Cmd ON Left
Reset Alarm
Cmd ON fast
Cmd ON fast
Cmd ON Left
Reset Alarm
Input 13 High/low Activation
N/A
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Input 14 Mapping
External
Fault 1
External
Fault 1
External
Fault 1
External
Fault 1
External
Fault 1
External
Fault 1
External
Fault 1
External
Fault 1
External
Fault 1
fb torque
open
External
Fault 1
Input 14 High/low Activation
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active Low
Active High
Input 15 Mapping
External
Supervision
External
Supervision
External
Supervision
External
Supervision
Drawer
position
Operation
External
Supervision
External
Supervision
Reset Alarm
External
Supervision
fb torque
close
External
Supervision
Input 15 High/low Activation
Active Low
Active Low
Active Low
Active Low
Active High
Active Low
Active Low
Active High
Active Low
Active Low
Active Low
Input 16 Mapping
Emergency
Stop
Emergency
Stop
Emergency
Stop
Emergency
Stop
Emergency
Stop
Emergency
Stop
Emergency
Stop
Emergency
Stop
Emergency
Stop
Emergency
Stop
Emergency
Stop
Input 16 High/low Activation
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Input 17 Mapping
Safety Circuit
Safety Circuit
Safety Circuit
Safety Circuit
Safety Circuit
Safety Circuit
Safety Circuit
Safety Circuit
Safety Circuit
Safety Circuit
Safety Circuit
Input 17 High/low Activation
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Active Low
Input 18 Mapping
Mode Switch
Local
Mode Switch
Local
Mode Switch
Local
Mode Switch
Local
Mode Switch
Local
Mode Switch
Local
Mode Switch
Local
Mode Switch
Local
Mode Switch
Local
Limit Open
Feedback
Limit Open
Feedback
Input 18 High/low Activation
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active Low
Active Low
Input 19 Mapping
Mode Switch
Remote
Mode Switch
Remote
Mode Switch
Remote
Mode Switch
Remote
Mode Switch
Remote
Mode Switch
Remote
Mode Switch
Remote
Mode Switch
Remote
Mode Switch
Remote
Limit Close
Feedback
Limit Close
Feedback
Input 19 High/low Activation
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active High
Active Low
Active Low
Relay Output Mapping
First Function Relay 42 Mapping
Contactor 1
Contactor 1
Contactor 1
Contactor 1
Contactor 1
Contactor 1
MCCB on
Contactor 1
Contactor 1
Contactor 1
Contactor 1
Second Function Relay 42 Mapping
None
None
None
None
None
None
None
None
None
None
None
First Function Relay 43 Mapping
ATEX
Redundancy
Output
Contactor 2
Contactor D
Contactor D
Bypass
Bypass
MCCB off
Contactor 2
Contactor 2
Contactor 2
Ready for
Switch on
Second Function Relay 43 Mapping
None
None
None
None
None
None
None
None
None
None
None
First Function Relay 45 Mapping
Warning
ATEX
Redundancy
Output
Contactor Y
Contactor 2
ATEX
Redundancy
Output
Left
Reset
Contactor Y
ATEX
Redundancy
Output
ATEX
Redundancy
Output
Warning
Second Function Relay 45 Mapping
Failure
(Output
Flashing)
None
None
None
None
None
None
None
None
None
Failure
(Output
Flashing)
First Function Relay 22 Mapping
Local
Local
ATEX
Redundancy
Output
ATEX
Redundancy
Output
Local
ATEX
Redundancy
Output
Local
ATEX
Redundancy
Output
Local
Local
Local
Second Function Relay 22 Mapping
None
None
None
None
None
None
None
None
None
None
None
Содержание EntelliPro ES Series
Страница 2: ...This page was intentionally left blank ...
Страница 8: ...This page was intentionally left blank ...
Страница 182: ...CHAPTER 4 COMMUNICATION EPOS MOTOR MANAGEMENT SYSTEM INSTRUCTION MANUAL 4 45 This page was intentionally left blank ...
Страница 255: ...EPOS MOTOR MANAGEMENT SYSTEM INSTRUCTION MANUAL 6 20 CHAPTER 6 ENTELLIPRO CP3 and CP5 APPLICATION ...