
3 - 16
Operation
K0260 Issue No. 8
3.7.1 Testing the Aircraft Static System
CAUTIONS:
1
O
BSERVE
ALL
SAFETY
PRECAUTIONS
DETAILED
IN
THE
A
IRCRAFT
M
AINTENANCE
M
ANUAL
.
2
W
HEN
USING
P
S
(
STATIC
ONLY
),
MAKE
SURE
THAT
THE
DIFFERENTIAL
PRESSURE
(Q
C
)
STAYS
WITHIN
THE
LIMITS
OF
THE
ASI.
1.
Remove the static blanking cap and switch ON.
2.
Connect the ADTS 505 to the Aircraft Static System.
Note:
If the static system under test contains an ASI, applying static (vacuum) to this instrument
generates a Q
C
differential pressure.
3.
Press
ALT/Ps
and make sure the display shows ALT Leak Measure.
Note:
To monitor the rate of change press
ROC/RATE Ps
after pressing
ALT/Ps
. The control rate of
change for altitude can be changed within the selected limits.
4.
If necessary, select [Units] in the Main Menu, press F1 [ft, kts, ft/min]. Press
CLEAR/QUIT
to go back
to the Main Menu.
5.
If necessary change the limits in the Main Menu, press F6 [More], F1 [Limits]. After setting the limits,
press repeatedly
CLEAR/QUIT
to go back to the Main Menu.
6.
Press
LEAK MEASURE/CONTROL
to select control mode and, using the numeric keys, set the control
aim. Press
ENTER
, the altitude changes to the control aim the rate of change slows as it gets near
the control aim and does not "overshoot" the aim value.
7.
Enter another aim or use the nudge facility to change the aim value. At the end of testing, press
GROUND
to return to atmospheric pressure.
8.
On completion of testing, select
GROUND
and wait for the `Safe at Ground' message to be displayed,
see 3.7.8., refit the static blanking cap.
Содержание Druck ADTS 505
Страница 1: ...GE Measurement Control Druck ADTS 505 Air Data Test Set User Manual K0260 ...
Страница 14: ...xii K0260 Issue No 8 Druck ADTS 505 User Manual ...
Страница 54: ...3 26 Operation K0260 Issue No 8 ...
Страница 55: ...Druck ADTS 505 User Manual 3 27 K0260 Issue No 8 3 ...
Страница 56: ...3 28 Operation K0260 Issue No 8 ...
Страница 66: ...5 4 Testing and Fault Finding K0260 Issue No 8 FIGURE 5 1 FAULT FINDING CHART ...
Страница 80: ...5 18 Testing and Fault Finding K0260 Issue No 8 Intentionally left blank ...
Страница 124: ...6 44 Reference and Specification K0260 Issue No 8 Intentionally left blank ...