B-58
L60 Line Phase Comparison System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
B391
...Repeated for module number 12
B394
...Repeated for module number 13
B397
...Repeated for module number 14
B39A
...Repeated for module number 15
B39D
...Repeated for module number 16
B3A0
...Repeated for module number 17
B3A3
...Repeated for module number 18
B3A6
...Repeated for module number 19
B3AC
...Repeated for module number 20
B3AF
...Repeated for module number 22
B3B2
...Repeated for module number 23
B3B5
...Repeated for module number 24
IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)
B400
Number of Status Indications in GGIO1
8 to 128
---
8
F001
8
B402
IEC 61850 GGIO1 Indication FlexLogic operands (128
items)
0 to 4294967295
---
1
F300
0
IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 Modules)
B5A0
IEC 61850 Configurable GOOSE Function
0 to 1
---
1
F102
0 (None)
B5A1
IEC 61850 Configurable GOOSE ID
---
---
---
F209
“GOOSEOut_x_”
B5C2
Configurable GOOSE Destination MAC Address
---
---
---
F072
0
B5C5
IEC 61850 Configurable GOOSE VLAN Transmit Priority
0 to 7
---
1
F001
4
B5C6
IEC 61850 Configurable GOOSE VLAN ID
0 to 4095
---
1
F001
0
B5C7
IEC 61850 Configurable GOOSE ETYPE APPID
0 to 16383
---
1
F001
0
B5C8
IEC 61850 Configurable GOOSE ConfRev
1 to 4294967295
---
1
F003
1
B5CA
IEC 61850 Configurable GOOSE Retransmission Curve
0 to 3
---
1
F611
3 (Relaxed)
B5CB
Configurable GOOSE dataset items for transmission
(64 items)
0 to 1008
---
1
F616
0 (None)
B60B
...Repeated for Module 2
B676
...Repeated for Module 3
B6E1
...Repeated for Module 4
B74C
...Repeated for Module 5
B7B7
...Repeated for Module 6
B822
...Repeated for Module 7
B88D
...Repeated for Module 8
IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (16 Modules)
B900
Configurable GOOSE dataset items for reception
(32 items)
0 to 197
---
1
F233
0 (None)
B920
...Repeated for Module 2
B940
...Repeated for Module 3
B960
...Repeated for Module 4
B980
...Repeated for Module 5
B9A0
...Repeated for Module 6
B9C0
...Repeated for Module 7
B9E0
...Repeated for Module 8
BA00
...Repeated for Module 9
BA20
...Repeated for Module 10
BA40
...Repeated for Module 11
BA60
...Repeated for Module 12
BA80
...Repeated for Module 13
BAA0
...Repeated for Module 14
BAC0
...Repeated for Module 15
BAE0
...Repeated for Module 16
Contact Inputs (Read/Write Setting) (96 Modules)
BB00
Contact Input 1 Name
---
---
---
F205
“Cont Ip 1“
BB06
Contact Input 1 Events
0 to 1
---
1
F102
0 (Disabled)
Table B–10: MODBUS MEMORY MAP (Sheet 50 of 65)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание L60
Страница 10: ...x L60 Line Phase Comparison System GE Multilin TABLE OF CONTENTS ...
Страница 57: ...GE Multilin L60 Line Phase Comparison System 2 27 2 PRODUCT DESCRIPTION 2 3 SPECIFICATIONS 2 ...
Страница 58: ...2 28 L60 Line Phase Comparison System GE Multilin 2 3 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Страница 100: ...3 42 L60 Line Phase Comparison System GE Multilin 3 3 DIRECT INPUT AND OUTPUT COMMUNICATIONS 3 HARDWARE 3 ...
Страница 482: ...6 26 L60 Line Phase Comparison System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 554: ...10 8 L60 Line Phase Comparison System GE Multilin 10 2 BATTERIES 10 MAINTENANCE 10 ...
Страница 674: ...B 110 L60 Line Phase Comparison System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 704: ...C 30 L60 Line Phase Comparison System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 720: ...E 10 L60 Line Phase Comparison System GE Multilin E 1 PROTOCOL APPENDIX E E ...
Страница 732: ...F 12 L60 Line Phase Comparison System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 742: ...H 8 L60 Line Phase Comparison System GE Multilin H 3 WARRANTY APPENDIX H H ...