![background image](http://html1.mh-extra.com/html/ge-multilin/850/850_communications-manual_3949189364.webp)
13-242
8 SERIES PROTECTIVE RELAY PLATFORM – COMMUNICATIONS GUIDE
CHAPTER 13: MODBUS MEMORY MAP
71202
0x79E1 Reset
0
1
1
FC265
0
1
Y
71203
0x79E2 Direction
0
2
1
FC164
0
1
Y
71204
0x79E3 Relays
0
0xFFFFFFFF
1
FC198
0
2
Y
71206
0x79E5 Block
0
0xC6CD00
1
FC142
0
2
Y
71208
0x79E7 Events
0
1
1
FC126
1
1
Y
71209
0x79E8 Targets
0
2
1
FC101
1
1
Y
Ground TOC 6
71223
0x79F6 Function
0
4
1
FC100
0
1
Y
71224
0x79F7 Signal Input
1
5
1
FC102A 1
1
Y
71225
0x79F8 Input
0
1
1
FC256
0
1
Y
71226
0x79F9 Pickup
50
30000
1
x CT
F13
1000
2
Y
71228
0x79FB Curve
0
21
1
FC161
2
1
Y
71229
0x79FC TDM
5
60000
1
F2
100
1
Y
71230
0x79FD Reset
0
1
1
FC265
0
1
Y
71231
0x79FE
Direction
0
2
1
FC164
0
1
Y
71232
0x79FF
Relays
0
0xFFFFFFFF
1
FC198
0
2
Y
71234
0x7A01 Block
0
0xC6CD00
1
FC142
0
2
Y
71236
0x7A03 Events
0
1
1
FC126
1
1
Y
71237
0x7A04 Targets
0
2
1
FC101
1
1
Y
Ground IOC 1
71323
0x7A5A Function
0
4
1
FC100
0
1
Y Y Y Y
71324
0x7A5B Signal Input
1
5
1
FC102A 1
1
Y
Y Y
71326
0x7A5D Pickup
50
30000
1
x CT
F13
1000
2
Y Y Y Y
71328
0x7A5F Direction
0
2
1
FC164
0
1
Y
Y Y
71329
0x7A60 Pickup Delay
0
6000000
1
s
F13
0
2
Y Y Y Y
71331
0x7A62 Dropout Delay
0
6000000
1
s
F13
0
2
Y Y Y Y
71333
0x7A64 Relays
0
0xFFFFFFFF
1
FC198
0
2
Y Y Y Y
71335
0x7A66 Block
0
0xC6CD00
1
FC142
0
2
Y Y Y Y
71337
0x7A68 Events
0
1
1
FC126
1
1
Y Y Y Y
71338
0x7A69 Targets
0
2
1
FC101
1
1
Y Y Y Y
Ground IOC 2
71352
0x7A77 Function
0
4
1
FC100
0
1
Y
Y Y
71353
0x7A78 Signal Input
1
5
1
FC102A 1
1
Y
Y Y
71355
0x7A7A Pickup
50
30000
1
x CT
F13
1000
2
Y
Y Y
71357
0x7A7C Direction
0
2
1
FC164
0
1
Y
Y Y
71358
0x7A7D Pickup Delay
0
6000000
1
s
F13
0
2
Y
Y Y
71360
0x7A7F Dropout Delay
0
6000000
1
s
F13
0
2
Y
Y Y
71362
0x7A81 Relays
0
0xFFFFFFFF
1
FC198
0
2
Y
Y Y
71364
0x7A83 Block
0
0xC6CD00
1
FC142
0
2
Y
Y Y
71366
0x7A85 Events
0
1
1
FC126
1
1
Y
Y Y
71367
0x7A86 Targets
0
2
1
FC101
1
1
Y
Y Y
Ground IOC 3
71381
0x7A94 Function
0
4
1
FC100
0
1
Y
Y
71382
0x7A95 Signal Input
1
5
1
FC102A 1
1
Y
Y
71384
0x7A97 Pickup
50
30000
1
x CT
F13
1000
2
Y
Y
Modbus
Address
Hex
Address
Description
Min
Max
Step Units
Format
Code
Factory
Default
Size in
Words
8
5
0
8
6
9
8
8
9
8
4
5
Содержание 850
Страница 26: ...3 6 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE REAL TIME CLOCK CHAPTER 3 TIME PROTOCOLS...
Страница 40: ...4 14 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE DNP IMPLEMENTATION CHAPTER 4 DNP PROTOCOL...
Страница 54: ...6 10 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE INTEROPERABILITY CHAPTER 6 IEC 60870 5 104...
Страница 86: ...8 24 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE THE IEC 61850 CONFIGURATOR CHAPTER 8 IEC 61850...
Страница 788: ...14 294 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE CHAPTER 14 FORMAT CODES...
Страница 868: ...B 74 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE PIXIT CHAPTER B IEC 61850 IMPLEMENTATION DETAILS...