13-300
8 SERIES PROTECTIVE RELAY PLATFORM – COMMUNICATIONS GUIDE
CHAPTER 13: MODBUS MEMORY MAP
83620
0xAA63 Relays
0
0xFFFFFFFF
1
FC198
0
2
Y
Y
83622
0xAA65 Block
0
0xC6CD00
1
FC142
0
2
Y
Y
83624
0xAA67 Events
0
1
1
FC126
1
1
Y
Y
83625
0xAA68 Targets
0
2
1
FC101
1
1
Y
Y
Current Demand 3
83645
0xAA7C Function
0
4
1
FC100A 0
1
Y
Y
83646
0xAA7D Signal Input
1
5
1
FC102A 1
1
Y
Y
83647
0xAA7E Measurement Type
0
2
1
FC254
0
1
Y
Y
83648
0xAA7F Thermal 90% Response
Time
0
4
1
FC255
2
1
Y
Y
83649
0xAA80 Time Interval
0
4
1
FC255
3
1
Y
Y
83650
0xAA81 Pickup
10
10000
1
A
F0
1000
1
Y
Y
83651
0xAA82 Relays
0
0xFFFFFFFF
1
FC198
0
2
Y
Y
83653
0xAA84 Block
0
0xC6CD00
1
FC142
0
2
Y
Y
83655
0xAA86 Events
0
1
1
FC126
1
1
Y
Y
83656
0xAA87 Targets
0
2
1
FC101
1
1
Y
Y
Current Demand 4
83676
0xAA9B Function
0
4
1
FC100A 0
1
Y
83677
0xAA9C Signal Input
1
5
1
FC102A 1
1
Y
83678
0xAA9D Measurement Type
0
2
1
FC254
0
1
Y
83679
0xAA9E Thermal 90% Response
Time
0
4
1
FC255
2
1
Y
83680
0xAA9F Time Interval
0
4
1
FC255
3
1
Y
83681
0xAAA0 Pickup
10
10000
1
A
F0
1000
1
Y
83682
0xAAA1 Relays
0
0xFFFFFFFF
1
FC198
0
2
Y
83684
0xAAA3 Block
0
0xC6CD00
1
FC142
0
2
Y
83686
0xAAA5 Events
0
1
1
FC126
1
1
Y
83687
0xAAA6 Targets
0
2
1
FC101
1
1
Y
Real Power Demand 1
83733
0xAAD4 Function
0
4
1
FC100A 0
1
Y Y Y Y
83734
0xAAD5 Signal Input
0
3
1
FC286
0
1
Y
Y
83735
0xAAD6 Measurement Type
0
2
1
FC254
0
1
Y Y Y Y
83736
0xAAD7 Thermal 90% Response
Time
0
4
1
FC255
2
1
Y Y Y Y
83737
0xAAD8 Time Interval
0
4
1
FC255
3
1
Y Y Y Y
83738
0xAAD9 Pickup
1
3000000
1
kW
F11
10000
2
Y Y Y Y
83740
0xAADB Relays
0
0xFFFFFFFF
1
FC198
0
2
Y Y Y Y
83742
0xAADD Block
0
0xC6CD00
1
FC142
0
2
Y Y Y Y
83744
0xAADF Events
0
1
1
FC126
1
1
Y Y Y Y
83745
0xAAE0 Targets
0
2
1
FC101
1
1
Y Y Y Y
Real Power Demand 2
83759
0xAAEE Function
0
4
1
FC100A 0
1
Y
83760
0xAAEF Signal Input
0
3
1
FC286
0
1
Y
83761
0xAAF0 Measurement Type
0
2
1
FC254
0
1
Y
83762
0xAAF1 Thermal 90% Response
Time
0
4
1
FC255
2
1
Y
83763
0xAAF2 Time Interval
0
4
1
FC255
3
1
Y
Modbus
Address
Hex
Address
Description
Min
Max
Step Units
Format
Code
Factory
Default
Size in
Words
8
5
0
8
6
9
8
8
9
8
4
5
Содержание 850
Страница 26: ...3 6 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE REAL TIME CLOCK CHAPTER 3 TIME PROTOCOLS...
Страница 40: ...4 14 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE DNP IMPLEMENTATION CHAPTER 4 DNP PROTOCOL...
Страница 54: ...6 10 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE INTEROPERABILITY CHAPTER 6 IEC 60870 5 104...
Страница 86: ...8 24 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE THE IEC 61850 CONFIGURATOR CHAPTER 8 IEC 61850...
Страница 788: ...14 294 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE CHAPTER 14 FORMAT CODES...
Страница 868: ...B 74 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE PIXIT CHAPTER B IEC 61850 IMPLEMENTATION DETAILS...