CHAPTER B: IEC 61850 IMPLEMENTATION DETAILS
MICS
8 SERIES PROTECTIVE RELAY PLATFORM – COMMUNICATIONS GUIDE
B-3
ThHaNeutAlmPTUV
Third Harmonic Neutral Alarm
Undervoltage
27TN
-
-
-
Yes(1)
PTUF
Underfrequency
81U
Yes(6)
Yes(12)
Yes(4)
Yes(4)
FastPTUF
Fast Underfrequency
-
-
Yes(8)
-
-
HzBndPTUF
Frequency out of band
accumulation
81A
-
-
-
Yes(7)
PFRC
Rate of change of frequency 81R
Yes(6)
Yes(12)
Yes(1)
Yes(2)
PTRC
Protection trip conditioning
(Trip bus)
-
Yes(6)
Yes(6)
Yes(6)
Yes(6)
PTTR
Thermal Overload
49
-
Yes(2)
-
-
curPTTR
Transformer thermal O/L
49
Yes(1)
-
-
-
MotThmPTTR
Thermal Mode
49
-
-
Yes(1)
-
GenThmPTTR
Thermal Overload
49TOL
-
-
-
Yes(1)
WatPSDE
Wattmetric Ground Fault -
Sensitive Directional
Earthfault
32N
-
Yes(4)
-
-
NeutAdm
Neutral Admittance
21YN
-
Yes(3)
-
PDOP
Directional Power
32
Yes(2)
Yes
Yes(1)
Yes(2)
PMRI
Start Inhibit
66
-
-
Yes(1)
-
tripPDUP
Trip Underpower
37P
-
-
Yes(1)
-
almPDUP
Alarm Underpower
37P
-
-
Yes(1)
-
RctPwrTripPDUP
Reactive Power Trip
40Q
-
-
Yes(1)
Yes(1)
RctPwrAlmPDUP
Reactive Power Alarm
40Q
-
-
Yes(1)
Yes(1)
SeqShtdnPDUP
Sequential Shutdown
-
-
-
-
Yes(1)
PTUC
Undercurrent
37
-
-
Yes(1)
-
PDIF
Differential Protection
87
Yes(1)
-
-
-
PcntPDIF
Percent Differential
87T
Yes(1)
-
Yes(1)
Yes(1)
OvrlPcntPDIF
Overall Percent Differential
-
-
-
-
Yes(1)
LosExtPDIS
Loss of Excitation
40
-
-
-
Yes(2)
OOSPPAM
Out of Step - Phase angle
measuring
78
-
-
-
Yes(1)
ThHaVPHIZ
Third Harmonic Voltage
Difference
64TN
-
-
-
Yes(1)
HaDetPHAR
Harmonic Detection
-
-
-
-
Yes(6)
PVPH
Volts per Hertz
24
Yes(2)
-
Yes(1)
Yes(2)
F:Logical Nodes for
functional block
Description
ANSI
845
850
869
889
TurnFltFXOT
Stator Inter-turn Fault
-
-
-
Yes(1)
-
RunHrsFXOT
Generator Running Hours
-
-
-
-
Yes(1)
R:Logical Nodes for
protection functions
Description
ANSI
845
850
869
889
ndRDIR
Neutral Directional2
67N
Yes(1)
Yes(4)
Yes(1)
Yes(1)
gndRDIR
Ground Directional
67G
Yes(1)
Yes(2)
-
Yes(1)
ngseqRDIR
Negative Sequence
Directional
67_2
-
Yes(2)
-
Yes(1)
hseRDIR
Sensitive Ground Directional 67SG
-
Yes(1)
-
Yes(1)
phsRDIR
Phase Directional Overcurrent 67P
Yes(1)
Yes(4)
Yes(1)
Yes(1)
RREC
Autorecloser
79
-
Yes(2)
-
-
rptRFLO
Fault Report
-
-
Yes(15)
-
-
Содержание 850
Страница 26: ...3 6 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE REAL TIME CLOCK CHAPTER 3 TIME PROTOCOLS...
Страница 40: ...4 14 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE DNP IMPLEMENTATION CHAPTER 4 DNP PROTOCOL...
Страница 54: ...6 10 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE INTEROPERABILITY CHAPTER 6 IEC 60870 5 104...
Страница 86: ...8 24 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE THE IEC 61850 CONFIGURATOR CHAPTER 8 IEC 61850...
Страница 788: ...14 294 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE CHAPTER 14 FORMAT CODES...
Страница 868: ...B 74 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE PIXIT CHAPTER B IEC 61850 IMPLEMENTATION DETAILS...