13-256
8 SERIES PROTECTIVE RELAY PLATFORM – COMMUNICATIONS GUIDE
CHAPTER 13: MODBUS MEMORY MAP
73345
0x8240 Direction
0
2
1
FC164
0
1
Y
73346
0x8241 Pickup Delay
0
6000000
1
s
F13
0
2
Y
73348
0x8243 Dropout Delay
0
6000000
1
s
F13
0
2
Y
73350
0x8245 Relays
0
0xFFFFFFFF
1
FC198
0
2
Y
73352
0x8247 Block
0
0xC6CD00
1
FC142
0
2
Y
73354
0x8249 Events
0
1
1
FC126
1
1
Y
73355
0x824A Targets
0
2
1
FC101
1
1
Y
Negative Sequence IOC 15
73369
0x8258 Function
0
4
1
FC100
0
1
Y
73370
0x8259 Signal Input
1
5
1
FC102A 1
1
Y
73372
0x825B Pickup
50
30000
1
x CT
F13
1000
2
Y
73374
0x825D Direction
0
2
1
FC164
0
1
Y
73375
0x825E Pickup Delay
0
6000000
1
s
F13
0
2
Y
73377
0x8260 Dropout Delay
0
6000000
1
s
F13
0
2
Y
73379
0x8262 Relays
0
0xFFFFFFFF
1
FC198
0
2
Y
73381
0x8264 Block
0
0xC6CD00
1
FC142
0
2
Y
73383
0x8266 Events
0
1
1
FC126
1
1
Y
73384
0x8267 Targets
0
2
1
FC101
1
1
Y
Negative Sequence IOC 16
73398
0x8275 Function
0
4
1
FC100
0
1
Y
73399
0x8276 Signal Input
1
5
1
FC102A 1
1
Y
73401
0x8278 Pickup
50
30000
1
x CT
F13
1000
2
Y
73403
0x827A Direction
0
2
1
FC164
0
1
Y
73404
0x827B Pickup Delay
0
6000000
1
s
F13
0
2
Y
73406
0x827D Dropout Delay
0
6000000
1
s
F13
0
2
Y
73408
0x827F Relays
0
0xFFFFFFFF
1
FC198
0
2
Y
73410
0x8281 Block
0
0xC6CD00
1
FC142
0
2
Y
73412
0x8283 Events
0
1
1
FC126
1
1
Y
73413
0x8284 Targets
0
2
1
FC101
1
1
Y
Negative Sequence Directional OC 1
73541
0x8304 Signal Input
1
5
1
FC102A 1
1
Y
73542
0x8305 Pos-Seq Restraint
0
500
1
F3
63
1
Y
Y
73543
0x8306 Forward ECA
0
90
1
°Lag
F0
75
1
Y
Y
73544
0x8307 Forward Limit Angle
40
90
1
°
F0
90
1
Y
Y
73545
0x8308 Forward Pickup
50
30000
1
x CT
F3
50
1
Y
Y
73546
0x8309 Reverse Limit Angle
40
90
1
°
F0
90
1
Y
Y
73547
0x830A Reverse Pickup
50
30000
1
x CT
F3
50
1
Y
Y
73548
0x830B Block
0
0xC6CD00
1
FC142
0
2
Y
Y
73550
0x830D Events
0
1
1
FC126
1
1
Y
Y
73551
0x830E Targets
0
2
1
FC101
1
1
Y
Y
Negative Sequence Directional OC 2
73553
0x8310 Signal Input
1
5
1
FC102A 1
1
Y
73554
0x8311 Pos-Seq Restraint
0
500
1
F3
63
1
Y
Y
73555
0x8312 Forward ECA
0
90
1
°Lag
F0
75
1
Y
Y
73556
0x8313 Forward Limit Angle
40
90
1
°
F0
90
1
Y
Y
Modbus
Address
Hex
Address
Description
Min
Max
Step Units
Format
Code
Factory
Default
Size in
Words
8
5
0
8
6
9
8
8
9
8
4
5
Содержание 850
Страница 26: ...3 6 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE REAL TIME CLOCK CHAPTER 3 TIME PROTOCOLS...
Страница 40: ...4 14 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE DNP IMPLEMENTATION CHAPTER 4 DNP PROTOCOL...
Страница 54: ...6 10 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE INTEROPERABILITY CHAPTER 6 IEC 60870 5 104...
Страница 86: ...8 24 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE THE IEC 61850 CONFIGURATOR CHAPTER 8 IEC 61850...
Страница 788: ...14 294 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE CHAPTER 14 FORMAT CODES...
Страница 868: ...B 74 8 SERIES PROTECTIVE RELAY PLATFORM COMMUNICATIONS GUIDE PIXIT CHAPTER B IEC 61850 IMPLEMENTATION DETAILS...