RTP 4.3 J322- S22 ELEMENT AT PYRAMID TIMEOUT
S22 Element at Pyramid time out is the maximum time to wait for the lead
edge of the element to reach the Element Detect at Pyramid sensor
1. Check if the element spool is loaded properly.
Element spool is loaded properly
Yes
- Go to Step 2
No
- Remove the element spool and reinsert it properly
2. Do GP 6.4 to check S22 Element Detect at Pyramid sensor
This clears the fault
Yes
- Return to normal operation
No
- Go to step 3
3. Check the condition of the Element belt (PL 5.8). Check for missing or
loose teeth in the belt
Element belt is in good condition
Yes
- Go to Step 4
No
- Replace the belt (REP 3.6)
4. Do ADJ 1.17 Element Feed Belt Tension Adjustment
This clears the fault
Yes
- Return to normal operation
No
- Go to Step 5
5. Do GP 6.5 to check M10 Element feed belt Motor.
This clears the fault
Yes
- Return to normal operation
No
- Go to step 6
6. Go GP 6.4 to check S25 Belt Home sensor
This clears the fault
Yes
- Return to normal operation
No
- Go to step 7
7. Check the condition of the Element feed track assembly (PL 5.9)
Element feed track assembly is in good condition
Yes
- Go to Step 8
No
- Replace Element feed track assembly (REP 3.10)
8. Check the condition of the Element feed belt idler assembly (PL 5.9)
Element feed belt idler assembly is in good condition
Yes
- Go to Step 9
No
- Replace Element feed track assembly (REP 3.10)
9. Check the condition of the Element engagement guide (PL 5.9)
Element engagement guide is in good condition
Yes
- Go to Step 10
No
- Replace Element engagement guide (REP 3.13)
10. Check the condition of the Element belt idler (PL 5.9)
Element belt idler is in good condition
Yes
- Go to Step 11
No
- Replace Element belt idler (REP 3.11)
11. Check the condition of the Element sprocket nose sub-assembly (PL
5.9)
Element sprocket nose sub-assembly is in good condition
Yes
- Go to Step 12
No
- Replace Element sprocket nose sub-assembly (REP 3.12)
12. Do GP 6.3.5 FIRMWARE UPGRADE Procedure to Re-flash the
firmware for eWire.
This clears the fault
Yes
- Return to normal operation;
No
- Escalate to second level
Содержание StreamWire
Страница 9: ...GBC StreamWire 07 23 2020 Service Manual ix Notes...
Страница 87: ...GBC StreamWire 07 23 2020 RTPS 2 72 Notes...
Страница 89: ...Book Quality 07 23 2020 GBC StreamWire 3 2 This page intentionally left blank...
Страница 343: ...General Procedures and Information 07 23 2020 GBC StreamWire 6 6 GP 6 1 4 Service Menu Flowchart...
Страница 420: ...GBC StreamWire 06 25 2019 General Procedures and Information 6 83 A C Board Test Points B Board Test Points...
Страница 428: ...GBC StreamWire 12 18 2018 Wiring Data 7 3 o System Wiring...
Страница 429: ...Wiring Data 12 18 2018 GBC StreamWire 7 4 o Element Feeder Module...
Страница 430: ...GBC StreamWire 12 18 2018 Wiring Data 7 5 o Element Transfer Module...
Страница 431: ...Wiring Data 12 18 2018 GBC StreamWire 7 6 o Knife Module...
Страница 432: ...GBC StreamWire 12 18 2018 Wiring Data 7 7 o Closer Module...
Страница 433: ...Wiring Data 12 18 2018 GBC StreamWire 7 8 o Holder Module...
Страница 434: ...GBC StreamWire 12 18 2018 Wiring Data 7 9 o Book Drawer...
Страница 435: ...Wiring Data 12 18 2018 GBC StreamWire 7 10 o Paper Transport Module...
Страница 436: ...GBC StreamWire 12 18 2018 Wiring Data 7 11 o Sheet Tappers Module...
Страница 437: ...Wiring Data 12 18 2018 GBC StreamWire 7 12 o Deflector Module...
Страница 438: ...GBC StreamWire 12 18 2018 Wiring Data 7 13 o Stacker Module...
Страница 439: ...Wiring Data 12 18 2018 GBC StreamWire 7 14 o Alignment Module...
Страница 440: ...GBC StreamWire 12 18 2018 Wiring Data 7 15 o Interlock AC and LCD Connections...
Страница 442: ...Installation Instructions 03 26 2019 GBC StreamWire 8 2 This page intentionally left blank...