General Procedures and Information
6-43
4. Check the tightness of the set screw of pulleys on the stepper motor
shaft. Check tightness of the set screws on pulleys driven by the
motor timing belt.
All the set screws are secured tightly
Yes
- Go to Step 5
No
- Tighten the loose set screw and repeat Step 1
5. For the motor in question, check the DIP switch settings for the
corresponding Driver Board. Refer to the table below to find the
correct DIP Switch settings.
DIP 1
DIP 2
DIP 3
DIP 4
DIP 5
M3
OFF
ON
OFF
ON
ON
M5
OFF
ON
OFF
ON
OFF
All the DIP switch settings are correct
Yes
- Go to Step 6
No
- Correct the DIP switch and repeat Step 1
6. Check if there is power to the Driver board. LED 1 on the Driver board
should be lit.
If LED 1 is lit, it means there is 24V DC power to the Driver board
from the Main Control board.
If LED 2 is lit, it means there is a fault with either the Driver board or
the stepper motor.
LED 1 is not Lit
- Go to Step 7
LED 1 is Lit
- Go to Step 8
7. Check that the cable(s) connecting the Driver Board 24 VDC signal to
the Main Control Board are intact. Refer to the motor cables table to
identify the appropriate cable part numbers, refer to
The cables look okay
Yes
- Go to Step 8
No
- Replace the faulty cable and repeat Step 1
8. Check that the cable(s) connecting the Driver Board Control signal to
the Main Control Board are intact. Refer to the motor cables table to
identify the appropriate cable part numbers,
The cables look okay
Yes
- Go to Step 9
No
- Replace the faulty cable and repeat Step 1
firmware for the eWire
This clears the fault
Yes
- Resume normal operation
No
- Go to Step 10
10. Replace the driver board for the faulty motor, with DIP switch set
correctly for the position you are replacing. Refer to REP 9.6, Stepper
Driver Boards Replacement.
This clears the fault
Yes
- Resume normal operation
No
- Go to Step 11
11. Replace the faulty stepper motor
REP 5.5 for M3
REP 4.5 for M5
This clears the fault
Yes
- Resume normal operation
No
- Go to Step 12
12. Replace Main Control Board A (REP 11.1)
This clears the fault
Yes
- Resume normal operation
No
- Escalate to second level
Содержание StreamWire
Страница 9: ...GBC StreamWire 07 23 2020 Service Manual ix Notes...
Страница 87: ...GBC StreamWire 07 23 2020 RTPS 2 72 Notes...
Страница 89: ...Book Quality 07 23 2020 GBC StreamWire 3 2 This page intentionally left blank...
Страница 343: ...General Procedures and Information 07 23 2020 GBC StreamWire 6 6 GP 6 1 4 Service Menu Flowchart...
Страница 420: ...GBC StreamWire 06 25 2019 General Procedures and Information 6 83 A C Board Test Points B Board Test Points...
Страница 428: ...GBC StreamWire 12 18 2018 Wiring Data 7 3 o System Wiring...
Страница 429: ...Wiring Data 12 18 2018 GBC StreamWire 7 4 o Element Feeder Module...
Страница 430: ...GBC StreamWire 12 18 2018 Wiring Data 7 5 o Element Transfer Module...
Страница 431: ...Wiring Data 12 18 2018 GBC StreamWire 7 6 o Knife Module...
Страница 432: ...GBC StreamWire 12 18 2018 Wiring Data 7 7 o Closer Module...
Страница 433: ...Wiring Data 12 18 2018 GBC StreamWire 7 8 o Holder Module...
Страница 434: ...GBC StreamWire 12 18 2018 Wiring Data 7 9 o Book Drawer...
Страница 435: ...Wiring Data 12 18 2018 GBC StreamWire 7 10 o Paper Transport Module...
Страница 436: ...GBC StreamWire 12 18 2018 Wiring Data 7 11 o Sheet Tappers Module...
Страница 437: ...Wiring Data 12 18 2018 GBC StreamWire 7 12 o Deflector Module...
Страница 438: ...GBC StreamWire 12 18 2018 Wiring Data 7 13 o Stacker Module...
Страница 439: ...Wiring Data 12 18 2018 GBC StreamWire 7 14 o Alignment Module...
Страница 440: ...GBC StreamWire 12 18 2018 Wiring Data 7 15 o Interlock AC and LCD Connections...
Страница 442: ...Installation Instructions 03 26 2019 GBC StreamWire 8 2 This page intentionally left blank...