74
Document: GAR_SM_4601777 (4/16)
Component Check Procedures
Section 7
Reading the LEDs - SSRB
The SSRB has one LED per heater. The LEDs blink in proportion to the power being delivered to each heater:
•
An LED that is always on (or nearly always) is receiving maximum power.
•
An LED that is off is receiving no power.
•
An LED that is blinking is receiving some power.
Location
Color
Name
Meaning
1
Red
Pwr Synch
Blinks when high voltage detected from SSRB
2
Red
Debug 1
On during normal operation
3
Red
Debug 2
Blinks during normal operation
4
Red
Debug 3
Blinks rapidly during normal operation
5
Red
Debug 4
Blinks when SIB software updates, lights if error between SIB and UI
6
Amber
Home
On until platen is at the home switch (or lower)
Содержание XPE12