Component Check Procedures
Section 7
Reading the LEDs - SIB - Diagnose Platen Errors
Position Indicators
Check the amber LEDs 6 & 7 on the SIB:
LED 6 (H
OME
)
LED 7 (U
PPER
)
ON
OFF
P
LATEN
MUST
BE
UP
(
AT
OR
ABOVE
THE
UPPER
SWITCH
)
OFF
ON
P
LATEN
MUST
BE
DOWN
(
AT
OR
BELOW
THE
HOME
SWITCH
)
ON
ON
P
LATEN
MUST
BE
BETWEEN
THE
HOME
AND
UPPER
SWITCHES
OFF
OFF
E
RROR
-
AT
LEAST
ONE
LED
MUST
BE
ON
If the platen position does not correspond to the LED pattern, check that the Position Sensor connector is properly
seated on the SIB (front left corner) and that it is wired correctly.
Motion Indicators
Check the LEDs 10, 11 & 12 on the SIB:
LED #
C
OLOR
10
B
LUE
M
OTOR
IS
MOVING
DOWN
11
G
REEN
M
OTOR
IS
MOVING
UP
12
R
ED
E
RROR
-
MOTOR
IS
OVERCURRENT
If LED 10 or 11 is lit, the motor is trying to move the platen. If LED 10 is lit and platen is at the bottom the motor
may be on the lower overtravel switch. Similarly, if LED 11 is lit and platen is fully open the motor may be on the
upper overtravel switch.
If LED 12 is lit or blinking while the platen is moving, the SIB has detected an overcurrent condition, and there may
be binding or an obstruction at some part of the mechanism.
Check that the motor encoder connector is properly seated on the SIB (front middle-right) and that it is wired
correctly.