54
Document: GAR_SM_4601777 (4/16)
Troubleshooting
Section 5
Temperature Issues
Problem
Possible Cause
Action
Grill or upper platen too
hot
Recipe set points are high
Use temperature status screen to check
zone temperatures versus set point
Temperature calibration
incorrect
Reset off sets to default value and verify
temperatures
Partial load cooking driving
temperature on unused zone
Cook full load and recheck zone
temperatures
Thermocouple wiring incorrect
Select the temperature status screen.
Place a wet rag onto each thermocouple
location and watch for a temperature
drop at that zone.
Thermocouple wiring incorrect
(Grill or upper platen)
Use wiring diagram to check that
thermocouple wiring is correct
Intermittent thermocouple fault Check wiring and connections to SIB
Heater wiring incorrect
Use wiring diagram to check Triac
mapping. Place a wet rag onto each
thermocouple location and watch for
LED activity on SSRB at the correct
location
High temperature switch
defective
Check state of switch, measuring
current will confi rm the switch is below
trip point.