background image

formerly DOUGHPRO. New Name. Same Quality. Superior Service.

proluxe.com

Operations  Manual

Model: SL1577

TB

Split Lid Grill

revC - 101416

Summary of Contents for TACO BELL PROGRILL SL1577TB

Page 1: ...formerly DOUGHPRO New Name Same Quality Superior Service proluxe com Operations Manual Model SL1577TB Split Lid Grill revC 101416 ...

Page 2: ... the power switch which will illuminate when turned on The display flashes and shows left preset timer during warm up Pre heat temperature time will be 40 50 minutes When the set point is reached the display stops flashing and beeps 3 times Step 4 Operation Simply place product on either side of the grill close lid and press the desired pre set time cycle 10 or 20 seconds After the time cycle is f...

Page 3: ...t is turned on All preset LED s are turned off and the temperature set point is changed to the clean set point of 275 F This also initiates the cool down to clean set point condition as well the display starts flashing until the clean set point is reached To stop the clean cycle simply press the CLEAN button once to deactivate the clean cycle The CLEAN LED is turned off the preset LED s are restor...

Page 4: ... temperature of the UPPER PLATENS Press the TEMPERATURE button and the ARROW UP button at the same time 2 To find the temperature of the LOWER PLATENS Press the TEMPERATURE button and the ARROW DOWN button at the same time 275 is the factory default temp for the CLEAN cycle To change the CLEAN cycle temp simultaneously hold down the TEMP and CLEAN buttons for 15 seconds The current temp setting wi...

Page 5: ...timer button and continue to hold both for 5 seconds The digital displays will now read their preset times as shown here Each side is capable of having up to 4 different settings making a total of 8 set times Now using the ARROW buttons you can set your desired time Once you have set the desired time simply press the TEMP button the unit will display the new set time IMPORTANT NOTE When adjusting ...

Page 6: ...t Upper Platen has the open sensor or probe same goes for the down arrow indicating Lower Platen Sensor in one of two zones lost it s continuity Depress Temp While depressing Temp depress either up or down arrow to locate error message PROB zone 1 Lower Platen zone 2 Left Upper Platen zone 3 right Upper Platen If occurred when depressing the up arrow indicates either the left or right Upper Platen...

Page 7: ...With use of a Ohm Meter a condinuity check must check at the cold pins of the heater where the heater wire is brazed at the cold pin This will eliminate any other failue before the the heater element validating the loss off condinuity at the source Heater Element If so either the Upper left zone 2 right zone 3 or Lower 15 Either Upper Heater not coming down parallel to the Lower Heater Platen Para...

Page 8: ...EXPSL1577TBA RC 101216 SHEET 1 OF 2 79 2X 74 2X 73 2X 46 2X 55 2X 54 2X 40 70 4X 1 28 4X 72 42 2X 4X 2X 63 52 4X 71 75 4X 3 64 77 52 12X 45 76 78 2 68 A1 A2 ...

Page 9: ... 2X 56 2X 33 16 84 6X 87 80 70 34 35 71 82 86 83 22 2X 21 2X 20 2X 5 2X 2X 14 92 53 6X 31 6X 93 6X 3X 95 69 48 84 30 10 8X 66 65 3X 13 3X 9 6X 4 35 39 34 2X 48 17 2X 2X 37 19 18 2X 44 29 89 3X 90 17 3X 3X 91 36 4X 41 49 32 2X 15 12X 24 2X 23 2X 26 29 2X 58 61 59 61 59 25 27 60 61 60 59 4X 10 2X 47 38 6X 31 6X 53 62 2X 50 2X 11 4X 57 2X 67 81 A7 A4 A8 A3 ...

Page 10: ...29 BUSHING TEFLON 3 4 LONG 110113441 110113441 6 30 GREASE TRAY 110115505 110115505 1 31 NUT HEX 6 32 NH632 NH632 12 32 TOP LINK 110115508 110115508 2 33 WIRE HARNESS 1101102050 1101102050 1 34 UPPER LEVELING BRACKET 110115510 110115510 2 35 UPPERLEVELING SHIM 110115557 110115557 2 36 PIN PIVOT FRONT 11017088865 11017088865 2 37 BOLT HEX 5 16 18 X 1 STAINLESS STEEL BH516181S BH516181S 4 38 BACK CO...

Page 11: ...5513 1 82 SCREW SET 3 8 16 x 1 2 SST381612 SST381612 2 83 RTD SENSOR 1108881101 1108881101 2 84 SCREW PAN HEAD PHILLIPS 10 24X3 8 STAINLESS STEEL SP102438S SP102438S 12 85 SHROUD LEFT ASSEMBLY 11016546454 11016546454 1 86 SHROUD RIGHT ASSEMBLY 11016546455 11016546455 1 87 INSULATION UPPER PLATEN 110888251 110888251 2 88 CLEVIS ASSEMBLY LEFT HAND 110115503 110115503 1 89 CLEVIS ASSEMBLY RIGHT HAND ...

Page 12: ......

Page 13: ...mpany s products the following instructions must be adhered to First contact our customer service department for approval and a return authorization number Please have the serial number of your item available at that time All merchandise must be shipped freight prepaid by customer or service agency Subject to the inspection of the product by the company a restocking charge of 20 of the Net purchas...

Reviews: