IF 632 Installation and Operation Manual
Release: 3 01/31/01
18
SYSTEM OVERVIEW
IF 632
Control Panel
The Gamewell IDENTIFLEX 632 system (IF632), is an Analog/Addressable,
microprocessor based, fire alarm control panel. It is designed to monitor and control
up to 1008 analog addressable input/output points. It can also accommodate up to 56
input or output circuits. The IF632 system is designed to meet the requirements of
medium sized applications. It provides the user with a full range of features including;
self-configuring, self-monitoring, and self-testing. Some of the many other features
the IF632 system offers include; User prompted operation, a 4 line by 40 character
LCD display, programmable input/output circuit types, a 1000 event history log,
Default Alarm Mode, Multiple levels of password protection, easy access wiring
terminals, universal module mounting and many more. All of the IF632 system
functions are fully field programmable from the front panel or may be configured via
computer using its built in, Upload/Download feature.
Modular
Construction
The design of the system utilizes a modular building block approach. The base system
consists of the Common Control, the Main Power Supply and the system cabinet with
two card bays and an Analog Addessable card installed. The second bay will
accommodate another Analog Addessable card or any of the 2, 4 or 8 circuit modules
available for the IF632 system. With the addition of an expander cabinet the system
allows for up to 6 additional circuit modules with up to 48 individual circuits or
Auxilliary Power Supplies. Through selection of individual F600 series I/O modules
(i.e. initiating, indicating, control, etc) the user can customize the control panel for
each specific application.
SmartStart
The IF632 control panel utilizes a unique initialization programming process,
SmartStart
. This initialization process stores the project specific system
configuration in memory. Then a control-by-event table is automatically created that
allows any system input to activate the system outputs. Upon completion of the
initialization process the system is completely operable in a general alarm situation
with the control-by-event data tables protected in non-volatile memory
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com
Содержание IDENTIFLEX 632
Страница 25: ...Section 2 IDENTIFLEX 632 System Operation Technical Manuals Online http www tech man com firealarmresources com...
Страница 37: ...Section 3 IDENTIFLEX 632 Installation Technical Manuals Online http www tech man com firealarmresources com...
Страница 71: ...Section 4 IDENTIFLEX 632 System Test Mode Technical Manuals Online http www tech man com firealarmresources com...
Страница 85: ...Section 5 IDENTIFLEX 632 Programming Technical Manuals Online http www tech man com firealarmresources com...
Страница 145: ...Section 5A IDENTIFLEX 632 Appendix Technical Manuals Online http www tech man com firealarmresources com...