112
CHAPTER 6 CLOCK MODULATOR
Figure 6.3-2 shows the status of the modulator.
bit1
FMOD:
Frequency
modulation
enable bit
"0": Frequency modulation disabled.
"1": Frequency modulation enabled.
Note: Do not set this bit to "1" with MB90F394H.
•
To enable the modulator in frequency modulation mode, FMOD must be set to "1".
•
Before the modulator can be enabled, the PLL must deliver a stable reference clock
(PLL lock time must be elapsed).
•
The specified PLL frequency range for frequency modulation mode is 15 MHz to 25
MHz.
•
Each PLL output frequency offers a set of possible modulation parameters. The
selected setting (CMPR register) and the PLL frequency must match.
Please refer to the CMPR register description.
•
Whenever the PLL output frequency is changed or the PLL is switched OFF e.g. in
power down modes, the modulator must be disabled before
→
FMOD=0 and
FMODRUN=0.
•
Before the modulator can be enabled, it must be switched from power down to active
mode by setting PDX to "1". And the startup time of 6
μ
s must be awaited.
Please refer to the application note for a description of the recommended startup
sequence.
•
Before the modulator can be enabled in frequency modulation mode, a proper setting
must be selected via the parameter register CMPR.
•
The modulator must not be set to frequency modulation and phase modulation mode
at the same time (FMOD=1, PDX=1 and PMOD=1). Before the modulator can be
enabled in frequency modulation mode (FMOD=1, PDX=1), the PMOD bit must be
set to "0".
•
After enabling the frequency modulation mode by setting FMOD to "1", the
modulator is calibrated. During this time, the clock is unmodulated. Therefore the
output clock does not switch immediately to modulated clock. The status of the
clock (frequency modulated / unmodulated) is indicated by the FMODRUN status
bit. Please refer to the FMODRUN bit description.
•
Due to the synchronization of the FMOD signal and the synchronized switching to
unmodulated clock, it takes less than 9
×
T0 (input clock period) before the clock
switches to unmodulated clock after the modulator is disabled. The modulator can be
disabled at any time.
•
Before changing the parameter register CMPR, the modulator must be disabled
→
FMOD=0 and FMODRUN=0.
bit0
PDX:
Power down bit
"0": Power down mode
"1": Power up
•
PDX is the power down signal for the modulator. Before the frequency modulation
mode can be enabled, this bit must be set to "1" and the startup time of 6
μ
s must be
awaited. Please refer to the application note for a description of the recommended
startup sequence.
•
For phase modulation mode (PMOD bit), the modulator must remain in power down
mode. I.e. PDX must be set to "0".
•
Before switching to power down mode (PDX=0), the modulator must be disabled
→
FMOD=0 and FMODRUN=0.
Table 6.3-1 Function of Each Bit of the Clock Modulator Control Register (3/3)
Bit name
Function
Содержание MB90390 Series
Страница 2: ......
Страница 4: ......
Страница 17: ...xiii APPENDIX D List of Interrupt Vectors 690 INDEX 695 ...
Страница 18: ...xiv ...
Страница 132: ...104 CHAPTER 5 CLOCKS ...
Страница 152: ...124 CHAPTER 6 CLOCK MODULATOR ...
Страница 210: ...182 CHAPTER 11 TIME BASE TIMER ...
Страница 218: ...190 CHAPTER 12 WATCHDOG TIMER ...
Страница 264: ...236 CHAPTER 14 16 BIT RELOAD TIMER WITH EVENT COUNT FUNCTION ...
Страница 274: ...246 CHAPTER 15 WATCH TIMER ...
Страница 306: ...278 CHAPTER 17 DTP EXTERNAL INTERRUPTS ...
Страница 338: ...310 CHAPTER 18 8 10 BIT A D CONVERTER ...
Страница 364: ...336 CHAPTER 19 UART0 UART1 ...
Страница 398: ...370 CHAPTER 20 UART2 UART3 Figure 20 5 2 ORE Set Timing Receive data RDRF ORE ...
Страница 432: ...404 CHAPTER 20 UART2 UART3 ...
Страница 482: ...454 CHAPTER 22 SERIAL I O ...
Страница 560: ...532 CHAPTER 24 STEPPING MOTOR CONTROLLER ...
Страница 582: ...554 CHAPTER 27 ROM MIRRORING MODULE ...
Страница 632: ...604 CHAPTER 29 EXAMPLES OF SERIAL PROGRAMMING CONNECTION ...
Страница 722: ...694 APPENDIX ...
Страница 723: ...695 INDEX The index follows on the next page This is listed in alphabetic order ...
Страница 740: ......