-12-
3.3.4.2. How to connect to power supply/signal terminal block
Remove the shield plate and connect the signal cable of path 1 and either of path 2 or the signal cable of resistance bulb to
signal terminal.
Re-attach the shield plate, and then connect the power cable to the power terminal.
Please prepare a flathead screwdriver (head size: 0.6 x 3.5mm) or a small-sized Phillips head screwdriver so as to tighten
the cable.
(1) Pull off the cable socket from the plug on the substrate with holding the right side of the socket by hand.
(2) If cable entry is closed, turn the screw counterclockwise to open.
(3) Insert the cable and turn the screw clockwise to fix the cable. Check that the cable does not come out.
(4) Install the cable socket side to the plug on the substrate.
(5) Fix the shield cable (green) of signal cable to the shield terminal.
Note) Make sure to conduct the procedure not to damage the printed-circuit board when you remove and install the cable
socket.
Cable socket
Shield plate