5.1.1. Mounting of detector
For sensor spacing, select either method in advance.
Calculate from flow transmitter
Turn ON the flow transmitter.
Enter the piping information, etc described in Section 4.9.2, and display it.
Display example: PROCESS SETTING S=16 (48mm)
During wiring work, be sure to turn the power off.
Calculate from our website.
Calculate from the CD attached to the equipment.
5.1.2. Image figure of mounting dimension
Type
FSS, FLS_12, FLS_22
FSSC
Mounting
method
V method
V method
Mounting
dimension
Mo
u
nting dimension
Mounting size
Type
FSSE, FSG_50, FSG_51
FSSD, FSD22, FSD32
Mounting
method
V method
V method
Mounting
dimension
Mouting size
Mo
u
nting dimension
Type
FSSC
FSSE, FSG50, FSG51
FSSH, FSD32
Mounting
method
Z method
Z method
Z method
Mounting
dimension
Mouting size
Mo
u
nting dimension
Type FSG31,
FSG32
FSG41
Mounting
method
V method
Z method
Mounting
dimension
Mounting size
Mouting
size
Mounting size