MT6M15962a
© Fuji Electric Co., Ltd. All rights reserved.
Figure 4-3 shows the typical application circuits of P626, P630, P631, P636 and P638 (6in1, with
temperature warning function type).
4-4
Fig.4-3 Typical application circuits of P626, P630, P631, P636 and P638 (6in1, with temperature
warning function)
(b) When not using the upper arms alarm
(a) When using the upper arms alarm
• If the temperature warning function is not used, open the WNG terminal.
If the WNG terminal is connected to the
V
CC
terminal, the consumption current
I
CC
increases
when the temperature of the IPM reaches the temperature warning level.