MHT260a (Engl.)
6-35
(4) Terminal function assignment
Set a number corresponding to signal name at desired system para., so that the function can be assigned to the terminal.
■
Setting example
Set “1” at the system para. 1 so that the terminal [CONT1] of the control input connector [CN1] functions as the input terminal for the run
command [RUN] signal.
■
Duplicated allocation
For the control input terminals, a signal cannot be assigned to more than one terminal simultaneously.
However, only the following signals can be assigned to more than one terminal:
・
Forced stop (10)
・
Free-run (54)
・
External fault input (34)
In case of the forced stop and the external fault input, the motor will stop forcibly if an input terminal is off.
In case of the free-run, the motor will be in free-run status if an input terminal is turned on.
If the signals other than the above have been assigned to more than one terminal, a control signal error [CtE] will be detected when turning
on power supply again.
For the control output terminals, a signal can be assigned to more than one terminal simultaneously.
Each terminal goes on or off at the same timing.
■
Always valid
The functions can be always effectire by setting a numerical value at the system para. 87 or 88.
Remark : If a number has been assigned to system para. for CONT signal assignment and system para. 87, 88 simultaneously, a control
signal error [CtE] will not be detected.
The assigned signal is always valid.
(5) System parameter 22 to 27
[
Basic type, SX bus, T-link
]
Para.
Name
Setting range
Initial value
Change
22
Parameter RAM storage 1
0: Not specified 1 to 99: Basic para. No.
0
Power
23
Parameter RAM storage 2
0: Not specified 1 to 99: Basic para. No.
0
Power
24
Parameter RAM storage 3
0: Not specified 1 to 99: Basic para. No.
0
Power
25
Parameter RAM storage 4
0: Not specified 1 to 99: Basic para. No.
0
Power
26
Parameter RAM storage 5
0: Not specified 1 to 99: Basic para. No.
0
Power
27
Parameter RAM storage 6
0: Not specified 1 to 99: Basic para. No.
0
Power
The contents of basic parameter is stored in the EEPROM (electrically erasable program read only memory) for retaining purpose at power
shut down. By specifying RAM, infinite rewriting is enable.
Specify a desired basic para. No. whose contents shall be stored in RAM storage to a system para. 22 to 27.
The contents of RAM storaged basic para. is initialized at power on.
Содержание Faldic-a RYS-R Series
Страница 1: ...RYS R Type User s Manual MHT260a Engl...
Страница 2: ...0...
Страница 78: ...0...
Страница 79: ...0 1 1 1 23 1 4 5 6 1 7 8 1 2 8 1 1 1 1 1 1 1 1 9 9 9 9 9 0 1 9 1 9 1 9 1 9 1 9 1...
Страница 81: ...0 1 20 3 4 2 20 5 20 5 4 2 3 4 4 6 4 72 4 7 4...
Страница 83: ...0 0 0 0 0 0 1 1 2 3 4 0 1 0 5 6 1 0 6 7 0 0 8 0 9 5 5 2 9 0 6 4 5 5 2 3 9 7 9 7 9 5 5 4 6 6...
Страница 84: ...6 7 A 6 B C D5 7 4 4 6 4 5 1 BE8 F70 CPU...
Страница 85: ...0 1 2 3 4 3 3 3 5 1 678...
Страница 86: ...0 1 1 0 1 2 2 3 4 5 4 5 2 1 678 4 9 95 9 9 1 9 1 3 3 1 4 5 06 2 3 0 06 4 4 0 0 0 0 0 3 4 0...
Страница 87: ...0 0 0 A A 0 0 0 0 0 0...