6-32
MHT260a (Engl.)
■
Connector pin layout
・
CN1 (lower side)
■
IQ area
Address
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
Current position, current deviation, basic para./ system para./ LS-Z phase pulse
(Low order word PC
←
Amplifier)
1
Current position, current deviation, basic para./ system para./ LS-Z phase pulse
(High order word PC
←
Amplifier)
2
Current speed (Low order word PC
←
Amplifier)
3
Current speed (High order word PC
←
Amplifier)
4
Current torque (PC
←
Amplifier)
5
−
Alarm code
−
6
−
CSEL
2
CSEL
1
CSEL
0
Current para. No.
7
OUT
3
OUT
4
OUT
5
OUT
6
OUT
7
OUT
8
OUT
9
OUT
10
OUT
11
OUT
12
OUT
13
OUT
14
OUT
15
OUT
16
Rewrite
end
Read
end
8
Station No. /basic para./system para. (Low order word PC
→
Amplifier)
9
Station No. /basic para./system para. (High order word PC
→
Amplifier)
10
Speed command (Low order word PC
→
Amplifier)
11
Speed command (High order word PC
→
Amplifier)
12, 13
−
14
SEL2 SEL1 SEL0
Para. No. setting
15
CONT
6
CONT
7
CONT
8
CONT
9
CONT
10
CONT
11
CONT
12
CONT
13
CONT
14
CONT
15
CONT
16
CONT
17
CONT
18
CONT
19
Rewrite
command
Read
command
Function (input signal) number assigned to
Function (output signal) assigned to
system para. 1 to 19 (CONT1 to CONT19)
system para. 31 to 46 (OUT1 to OUT16)
0: Not assigned
33: Clamping end
0: Not assigned
34: Alarm code 2
1: Run command [RUN]
34: External fault input
1: Ready [RDY]
35: Alarm code 3
2: Forward command [FWD]
42: 2nd origin
2: Indexing end [WPSET]
36: Alarm code 4
3: Reverse command [REV]
43: Override valid
13: Rewrite end
40: Origin LS detection
4: Auto start [START]
44: Override 1
14: Brake timing
41: Forced stop detection
5: Origin return [ORG]
45: Override 2
15: Dynamic braking
60: PD0
6: Origin LS [LS]
46: Override 4
16: Alarm detection
61: PD1
7: DIR
47: Override 8
17: Fixed point 1
62: PD2
9: ABS/INC
48: Manual index select 0
18: Fixed point 2
63: PD3
10: Forced stop [EMG]
49: Manual index select 1
22: Origin return end
64: PD4
11: Alarm reset [RST]
50: Deviation clear
23: Deviation zero
65: PD5
12: VEL0
51: X1
24: Speed zero
66: PD6
13: VEL1
52: X2
25: Speed arrive
67: PD7
14: ACC0
53: X3
26: Torque limit detection
68: PD8
16: Position preset
54: Free-run [BX]
27: Overload early warning
69: PD9
27: Pulse train ratio 1
55: Edit permit command
28: CPU ready
70: PD10
28: Pulse train ratio 2
29: Edit permit ON/OFF
71: PD11
29: P-action
30: Data error
72: PD12
30: Torque limit
31: Address error
73: PD13
31: Temporary stop
32: Alarm code 0
74: PD14
32: Positioning cancel
33: Alarm code 1
75: Position preset end
*CB
25
*CA
23
*FZ
21
*FB
19
*FA
17
BAT−
15
P5
13
MON1
11
M24
9
OUT2
7
CONT5
5
CONT3
3
CONT1
1
M5
12
MON2
10
P24
8
OUT1
6
CONT4
4
CONT2
2
24
CA
22
FZ
20
FB
18
FA
16
BAT+
14
26 M5
CB
SX bus
(SX
bus direct
connection
)
Содержание Faldic-a RYS-R Series
Страница 1: ...RYS R Type User s Manual MHT260a Engl...
Страница 2: ...0...
Страница 78: ...0...
Страница 79: ...0 1 1 1 23 1 4 5 6 1 7 8 1 2 8 1 1 1 1 1 1 1 1 9 9 9 9 9 0 1 9 1 9 1 9 1 9 1 9 1...
Страница 81: ...0 1 20 3 4 2 20 5 20 5 4 2 3 4 4 6 4 72 4 7 4...
Страница 83: ...0 0 0 0 0 0 1 1 2 3 4 0 1 0 5 6 1 0 6 7 0 0 8 0 9 5 5 2 9 0 6 4 5 5 2 3 9 7 9 7 9 5 5 4 6 6...
Страница 84: ...6 7 A 6 B C D5 7 4 4 6 4 5 1 BE8 F70 CPU...
Страница 85: ...0 1 2 3 4 3 3 3 5 1 678...
Страница 86: ...0 1 1 0 1 2 2 3 4 5 4 5 2 1 678 4 9 95 9 9 1 9 1 3 3 1 4 5 06 2 3 0 06 4 4 0 0 0 0 0 3 4 0...
Страница 87: ...0 0 0 A A 0 0 0 0 0 0...