5-50
MHT260a (Engl.)
!
(5) Auto start [START]
!
!
Sets the station number in the specified rewrite data area (see
"
table below).
!
!
Select the rotational speed at VEL0 and VEL1 (see
#
table below).
!
!
The motor starts rotation at the ON edge of [START] signal (at bit 1 in word +4) (see
$
table below).
!
!
(6) Manual feed
!
The rotational speed at forward [FWD] and reverse [REV] command is specified by the speed command (see
"
table below) while
multistep speed selection [X1] is off.
!
Turn on the bit 1 only in word +5 position only in the read/rewrite data select area.
!
After the rewrite command has been turned on, the speed is determined by
"
(in 1 [r/min] step).
!
!
The [X1] is at bit A in word +4 (at factory setting) position.
!
!
WB area (at factory setting)
!
Address
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
+0
!
RDY
!
WPSET
!
CPU
!
ready
!
Alarm
!
detect
!
Address
!
error
!
%
!
%
!
LS
!
detect
!
EMG
!
detect
!
Data
!
error
!
%
!
%
!
%
!
%
!
%
!
%
+1
!
%
!
ALM4
!
ALM3
!
ALM2
!
ALM1
!
ALM0
!
Rewrite
!
end
!
Read
!
end
!
%
+2
!
Read data (High order word PC
!
Amplifier)
+3
Read data (Low order word PC
!
Amplifier)
+4
RUN START FWD
REV
ORG
EMG
RST
VEL0 VEL1
DIR
X1
Position
preset
%
%
%
%
+5
%
Read/rewrite data select
Rewrite
command
Read
command
Address No.
+6
Rewrite data (High order word PC
"
Amplifier)
+7
Rewrite data (Low order word PC
"
Amplifier)
!
"
$
#
&
'
(
Current value
!
The current value of various data can be selected at on/off of bit 1 to 5 in word +5.
!
The selected current value can be read out at the ON edge of read command at bit 7 in word +5 position.
!
Once the read command is turned on, the data can be read out continuously.
!
!
Read/rewrite data select
!
+1
!
+2
!
+3
!
+4
!
+5
!
WB area (when reading)
!
WB area (when rewriting)
!
OFF
!
OFF
!
OFF
!
OFF
!
OFF
!
Current feedback position
!
-
!
OFF
!
OFF
!
OFF
!
OFF
!
ON
!
Feedback speed
!
-
!
OFF
!
OFF
!
OFF
!
ON
!
OFF
!
Torque command
!
-
!
OFF
!
OFF
!
OFF
!
ON
!
ON
!
Deviation amount
!
-
!
OFF
!
OFF
!
ON
!
OFF
!
OFF
!
LS-Z phase pulse
!
-
!
!
!
!
!
!
!
!
OFF
!
ON
!
OFF
!
ON
!
ON
!
-
!
-
!
OFF
!
ON
!
ON
!
OFF
!
OFF
!
-
!
-
!
OFF
!
ON
!
ON
!
OFF
!
ON
!
-
!
-
!
OFF
!
ON
!
ON
!
ON
!
OFF
!
Current command position
!
-
!
OFF
!
ON
!
ON
!
ON
!
ON
!
Command speed
!
-
!
ON
!
OFF
!
OFF
!
OFF
!
OFF
!
-
!
Speed command [FWD/REV]
!
!
Содержание Faldic-a RYS-R Series
Страница 1: ...RYS R Type User s Manual MHT260a Engl...
Страница 2: ...0...
Страница 78: ...0...
Страница 79: ...0 1 1 1 23 1 4 5 6 1 7 8 1 2 8 1 1 1 1 1 1 1 1 9 9 9 9 9 0 1 9 1 9 1 9 1 9 1 9 1...
Страница 81: ...0 1 20 3 4 2 20 5 20 5 4 2 3 4 4 6 4 72 4 7 4...
Страница 83: ...0 0 0 0 0 0 1 1 2 3 4 0 1 0 5 6 1 0 6 7 0 0 8 0 9 5 5 2 9 0 6 4 5 5 2 3 9 7 9 7 9 5 5 4 6 6...
Страница 84: ...6 7 A 6 B C D5 7 4 4 6 4 5 1 BE8 F70 CPU...
Страница 85: ...0 1 2 3 4 3 3 3 5 1 678...
Страница 86: ...0 1 1 0 1 2 2 3 4 5 4 5 2 1 678 4 9 95 9 9 1 9 1 3 3 1 4 5 06 2 3 0 06 4 4 0 0 0 0 0 3 4 0...
Страница 87: ...0 0 0 A A 0 0 0 0 0 0...