MHT260a (Engl.)
6-33
(3) T-link
(a) System parameter 1 to 21, 56 to 59
Para.
Name
Setting range
Initial value
Change
01
CONT1 signal assignment
0 to 55 (in 1 step)
0
Power
02
CONT2 signal assignment
0 to 55 (in 1 step)
0
Power
03
CONT3 signal assignment
0 to 55 (in 1 step)
0
Power
04
CONT4 signal assignment
0 to 55 (in 1 step)
0
Power
05
CONT5 signal assignment
0 to 55 (in 1 step)
0
Power
06
CONT6 signal assignment
0 to 55 (in 1 step)
0
Power
07
CONT7 signal assignment
0 to 55 (in 1 step)
0
Power
08
CONT8 signal assignment
0 to 55 (in 1 step)
0
Power
09
CONT9 signal assignment
0 to 55 (in 1 step)
1
Power
10
CONT10 signal assignment
0 to 55 (in 1 step)
4
Power
11
CONT11 signal assignment
0 to 55 (in 1 step)
2
Power
12
CONT12 signal assignment
0 to 55 (in 1 step)
3
Power
13
CONT13 signal assignment
0 to 55 (in 1 step)
5
Power
14
CONT14 signal assignment
0 to 55 (in 1 step)
10
Power
15
CONT15 signal assignment
0 to 55 (in 1 step)
11
Power
16
CONT16 signal assignment
0 to 55 (in 1 step)
12
Power
17
CONT17 signal assignment
0 to 55 (in 1 step)
13
Power
18
CONT18 signal assignment
0 to 55 (in 1 step)
7
Power
19
CONT19 signal assignment
0 to 55 (in 1 step)
51
Power
20
CONT20 signal assignment
0 to 55 (in 1 step)
16
Power
21
CONT21 signal assignment
0 to 55 (in 1 step)
0
Power
56
CONT22 signal assignment
0 to 55 (in 1 step)
0
Power
57
CONT23 signal assignment
0 to 55 (in 1 step)
0
Power
58
CONT24 signal assignment
0 to 55 (in 1 step)
0
Power
59
CONT25 signal assignment
0 to 55 (in 1 step)
0
Power
Function (input signal) number assigned to
Function (output signal) assigned to
system para. 1 to 21 (CONT1 to CONT21)
system para. 31 to 51 (OUT1 to OUT21)
system pwa. 56 to 59 (CONT22 to CONT25)
0: Not assigned
33: Clamping end
0: Not assigned
34: Alarm code 2
1: Run command [RUN]
34: External fault input
1: Ready [RDY]
35: Alarm code 3
2: Forward command [FWD]
42: 2nd origin
2: Indexing end [WPSET]
36: Alarm code 4
3: Reverse command [REV]
43: Override valid
13: Rewrite end
40: Origin LS detection
4: Auto start [START]
44: Override 1
14: Brake timing
41: Forced stop detection
5: Origin return [ORG]
45: Override 2
15: Dynamic braking
60: PD0
6: Origin LS [LS]
46: Override 4
16: Alarm detection
61: PD1
7: DIR
47: Override 8
17: Fixed point 1
62: PD2
9: ABS/INC
48: Manual index select 0
18: Fixed point 2
63: PD3
10: Forced stop [EMG]
49: Manual index select 1
22: Origin return end
64: PD4
11: Alarm reset [RST]
50: Deviation clear
23: Deviation zero
65: PD5
12: VEL0
51: X1
24: Speed zero
66: PD6
13: VEL1
52: X2
25: Speed arrive
67: PD7
14: ACC0
53: X3
26: Torque limit detection
68: PD8
16: Position preset
54: Free-run [BX]
27: Overload early warning
69: PD9
27: Pulse train ratio 1
55: Edit permit command
28: CPU ready
70: PD10
28: Pulse train ratio 2
29: Edit permit ON/OFF
71: PD11
29: P-action
30: Data error
72: PD12
30: Torque limit
31: Address error
73: PD13
31: Temporary stop
32: Alarm code 0
74: PD14
32: Positioning cancel
33: Alarm code 1
75: Position preset end
T-link
(
T-link direct
connection
)
Содержание Faldic-a RYS-R Series
Страница 1: ...RYS R Type User s Manual MHT260a Engl...
Страница 2: ...0...
Страница 78: ...0...
Страница 79: ...0 1 1 1 23 1 4 5 6 1 7 8 1 2 8 1 1 1 1 1 1 1 1 9 9 9 9 9 0 1 9 1 9 1 9 1 9 1 9 1...
Страница 81: ...0 1 20 3 4 2 20 5 20 5 4 2 3 4 4 6 4 72 4 7 4...
Страница 83: ...0 0 0 0 0 0 1 1 2 3 4 0 1 0 5 6 1 0 6 7 0 0 8 0 9 5 5 2 9 0 6 4 5 5 2 3 9 7 9 7 9 5 5 4 6 6...
Страница 84: ...6 7 A 6 B C D5 7 4 4 6 4 5 1 BE8 F70 CPU...
Страница 85: ...0 1 2 3 4 3 3 3 5 1 678...
Страница 86: ...0 1 1 0 1 2 2 3 4 5 4 5 2 1 678 4 9 95 9 9 1 9 1 3 3 1 4 5 06 2 3 0 06 4 4 0 0 0 0 0 3 4 0...
Страница 87: ...0 0 0 A A 0 0 0 0 0 0...