![FRIEDLAND SA3 PLUS Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/friedland/sa3-plus/sa3-plus_installation-and-operating-manual_2332728029.webp)
27
SIREN OPERATING MODE
The siren can be switched back into operating mode
using either the Remote Control, Control Panel as
follows:
Remote Control:
Press and hold the button for approximately
6 seconds.
After approximately 6 seconds the Siren will produce
a single long beep to indicate that it has switched into
operating mode in a Disarmed state. The button must
be released during or immediately after the long beep,
otherwise the system will switch into an Armed state.
Remote Control:
With the system in Standby with the Power LED ON:
Press , ,
to enter Test mode. The Arm and Part-Arm LEDs will
flash.
Press to switch the Siren between Service mode
and Operating mode. LED 5 will illuminate to show
that the appropriate signal is being transmitted.
After approximately 6 seconds the Siren will produce
a single long beep to indicate that it has switched into
operating mode in a Disarmed state.
Press to return to Standby mode.
BATTERY MONITORING
All system devices continuously monitor their battery
condition. The Control Panel also monitors the battery
condition of all PIR and Magnetic detectors. If the
battery level of any device drops below acceptable
levels then its low battery indication will be activated.
In addition if any PIR or Magnetic Contact detector
has a low battery status it will be indicated on the
‘LOW BAT’ LED on the Control Panel.
LED ON
Magnetic Contact
LED Flashing
PIR
When a low battery indicator is activated the device will
continue to operate normally for up to 2 weeks
(depending upon system use). However, the battery
for that device should be replaced as soon as possible.
Note: Before removing the battery cover on any device
to replace the battery ensure that the system is put into
Test mode to avoid initiating a Full Alarm condition.
The low battery indication for each system component
is as follows:
Remote Control
When the Remote Control is operated under low-
battery conditions the transmit LED will continue to
flash after the button has been released.
Under normal battery conditions the LED will extinguish
when the button is released.
PIR Movement Detector
Under low battery conditions the LED behind the
detector lens will flash when movement is detected to
indicate that the battery needs to be replaced.
Under normal battery conditions the LED does not
illuminate unless the PIR detector is in Walk Test mode.
Magnetic Contact Detector
Under low battery conditions, when the Detector is
activated, the transmit LED will be illuminated for
approximately 1s as the door/window is opened.
Under normal battery conditions the LED will not
illuminate as the Detector is operated, (unless the
Detector is in Test Mode with the battery cover removed).
User Access Code
1
2
3
4
ENTER
ESC
5