HARD-WIRED SIREN TEST
Press
The internal relay driving the hardwired siren will be
switched ON for a period of approximately 5 seconds.
Zone LED 2 will be illuminated during the test.
SIREN TEST
Press
The Control Panel alarm and the External Solar Siren
will be operated for a period of approximately 5
seconds with the external Solar Siren switching ON
and OFF a few seconds after the Control Panel.
Zone LED 3 will be illuminated during the test.
CONTROL PANEL LED TEST
Press
Zone LED 4 will illuminate.
Use and buttons to scroll through and
illuminate each LED in turn.
Press to exit LED test.
SOLAR SIREN SERVICE MODE
In order to remove the Solar Siren from the wall to
change the batteries. It is necessary to place the Siren
into Service mode to prevent the Tamper protection on
the Siren operating and triggering the siren.
Press to switch the Solar Siren between Service
Mode and normal Operating Mode.
Service Mode: The Solar Siren will produce two
short beeps followed by a single long beep 10
seconds later to indicate that it has switched into
service mode.
Operating Mode: After 10 seconds the Solar Siren
will produce one long beep followed immediately by
two short beeps to indicate that it has switched into
normal operating mode.
IMPORTANT: After changing the batteries and refitting
in position, the Solar Siren must be put back into normal
Operating Mode, otherwise the siren will not sound in
the event of an alarm condition.
VOICE DIALLER TEST
Press
Zone LED 6 will illuminate.
The voice dialler will call each activate number in the
dialling sequence in turn set number of times. When a
call is answered the recorded alarm message will be
replayed for the set Message Play Time. If the call is
unanswered or an acknowledgment signal is not
received from the number called, (i.e. by pressing the
button on the telephone keypad) the next number
in the sequence will be called.
Press to exit voice Dialler test.
FACTORY DEFAULTS
User Access Code:
1 2 3 4
Alarm Duration:
3 minutes
Hardwird Siren:
Equal to Alarm Duration
Zone Operating Mode:
Zones 1-6:
Intruder
Part-Arm:
Zones 1, 5, 6:
Disabled
Zones 2, 3, 4:
Active
Instant/Delay:
Zone 1:
Delay
Zones 2-6:
Instant
Entry/Exit Delay:
30s
Entry/Exit Warning Tone:
On
Zone Lockout:
On
Jamming Detection:
Off
Phone Numbers:
Not programmed
Message Play Time:
70s
Alarm Message:
Not programmed
Call Routing:
All numbers disabled
Call Attempts:
3
Dial Method:
Tone/DTMF
RESET FACTORY DEFAULT
CONDITIONS
1. Press , ,
to place the system in Test Mode.
2. Undo the Control Panel cover fixing screws and
open the cover.
19
ESC
3
4
ESC
5
6
2
User Access Code
?
?
?
?
ENTER