![FRIEDLAND SA3 PLUS Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/friedland/sa3-plus/sa3-plus_installation-and-operating-manual_2332728014.webp)
To select the required pulse count set DIP 5 of
SW3 as follows:
ON 1
pulse detection
OFF 2
pulse detection
Note: The higher the Pulse Count the more
movement will be necessary before the PIR
detector will trigger the alarm.
9. Connect the PP3 Alkaline battery to the battery
clip.
Note: When the 9V Alkaline battery is connected
the LED behind the lens will rapidly flash for
approximately 2-3 minutes until the PIR has
warmed-up and stabilised. The LED will then stop
flashing and turn OFF.
10. Check that the detector PCB is located and set in
the correct position to give the detection zone
pattern required.
To adjust the PCB position simply slide it up or down
ensuring that the location legs are aligned with the
required position number marked on the board.
PCB Position
Range
1
6m
3
9m
5
12m
11. Refit the PIR detector to the rear cover by offering
the detector up to the rear cover and locate the
clips in the top edge into the rear cover. Push the
lower edge of the detector into place and refit the
fixing screw in the bottom edge of the PIR to
secure in position. Do not over-tighten the fixing
screws as this may damage the casing.
TESTING THE PIR MOVEMENT
DETECTORS
Ensure that the system is in Test mode, (see page 18).
Ensure that the PIR is configured in Walk Test mode,
(i.e. DIP 4 of SW3 ON) and mounted in position on
the wall.
Allow 2-3 minutes for the detector to stabilise before
commencing testing.
1. Put the Control Panel into "Walk Test" mode by
pressing on the Control Panel.
The Panel will beep and the Zone 1 LED will
illuminate.
2. Walk into and move slowly around the protected
area, each time the detector senses movement the
LED behind the lens will flash. In addition, the
Control Panel will bleep twice to indicate that the
alarm signal has been received and the
appropriate zone LED which the detector is
configured for will illuminate.
Note: In normal operation, the LED will not flash
on movement detection. If necessary re-adjust the
detection pattern by changing the mounting
position of the PCB within the PIR housing.
3. Press on the Control Panel to exit Walk
Test mode.
4. Reconfigure the PIR Detector into Normal
operation mode and refit in position.
Note: When the detector is fully installed i.e. battery
cover is refitted; the unit will not detect movement
for approximately 45 seconds after each activation.
(This feature is present to conserve battery power
and maximise the battery life).
MAGNETIC CONTACT
DETECTOR(S)
OPTIONAL ACCESSORY - See page 30 for
details of accessories available.
The Magnetic Contact Set comprises two parts; a
Detector and a Magnet. They are designed to be
fitted to either doors or windows with the Magnet
screwed to the moving/opening part and the Contact
screwed to the fixed door or window frame.
12
DIP Switches
(SW2 and SW3)
PCB Board
(slides up and
down to adjust
position)
5
4
3
2
1
PCB Position
Indicator
(positions 1-5)
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
SW
3
SW
2
1
ESC