![FRIEDLAND SA3 PLUS Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/friedland/sa3-plus/sa3-plus_installation-and-operating-manual_2332728028.webp)
The Control Panel will acknowledge the signal by
beeping.
The Siren will also acknowledge the Disarm signal
beeping twice unless beep disable has been set.
Control Panel:
Press the ‘Disarm’ key, followed by the current
User Access code followed by the ‘Enter button
, ,
The Control Panel will acknowledge the signal by
beeping.
If the system has been triggered and an alarm
condition has occurred, then the appropriate LED will
be illuminated to indicate which zone(s) have triggered
the alarm. Make a note of the zone(s) indicated to
assist in tracing the cause of the alarm, before
pressing to clear the indication and return the
system to Standby.
PERSONAL ATTACK (PA) ALARM
A full Alarm condition can be immediately initiated at
any time (whether the system is Armed or Disarmed) in
the event of threat or danger by activating a Personal
Attack (PA) switch on either the Remote Control or the
Control Panel.
Remote Control:
Slide the Personal Attack switch upwards
Control Panel:
Press and hold the button for approximately
3 seconds.
The alarm will continue either for the alarm duration
when the system will automatically reset or until the
system is disarmed.
TAMPER
If the battery cover of any device (except a Remote
Control) is removed or if the Siren or Control Panel are
removed from the wall then a Full Alarm condition will
be initiated even if the system is Disarmed. The alarm
condition will continue either for the alarm duration
when the system will automatically reset or until the
system is Disarmed from the Remote Control or Control
Panel. The Tamper LED on the Control Panel will flash
to indicate the Tamper Alarm has been activated.
Note: The Tamper protection facility on the Siren
operates independently of the Control Panel. If the
Tamper on the Siren is activated this will not be
indicated at the Control Panel.
SIREN SERICE MODE
In order to remove the Solar Siren from the wall to
change the batteries, it is necessary to place the Siren
into Service mode to prevent the Tamper switch on the
Siren operating and triggering an alarm. When you
have completed any alterations to the system
remember to switch the siren back into Operating
mode.
The siren can be switched into service mode using
either the Remote Control or Control Panel as
follows:
Remote Control:
Press and hold the button for approximately
6 seconds.
The Siren will produce two short beeps as the button
is pressed followed by a single long beep
approximately 6 seconds later to indicate that it has
switched into service mode.
Control Panel:
With the system in Standby with the Power LED ON:
Press , ,
to enter Test mode. The Arm and Part-Arm LEDs will
flash.
Press to switch the Siren between Service mode
and Operating Mode. LED 5 will illuminate to show
that the appropriate signal is being transmitted.
The Siren will produce two short beeps as the button
is pressed followed by a single long beep
approximately 6 seconds later to indicate that it has
switched into service mode.
Press to return to Standby mode.
26
ESC
9
ESC
5
User Access Code
1
2
3
4
ENTER
User Access Code
1
2
3
4
ENTER