IMPORTANT: Do not drill the fixing holes with the
Control Panel in position; as the resulting dust and
vibration may damage the Control Panel’s internal
components and invalidate the guarantee.
4. Fit two 18mm No.4 screws into the top holes until
almost fully home and hang the Control panel over
these screws using the two keyhole slots in the top
corners of the panel casing.
5. Route the cable from the Power Supply Unit up
behind and on the right hand side of the Control
Panel and connect the plug to the DC power socket
in the panel. Ensuring that the cable is not trapped
between the panel and the wall.
6. Fix the Panel to the wall using two 18mm No.4
screws in the lower two fixing holes in the panel and
tighten the upper fixing screws until they just grip
the casing. Do not over tighten the fixing screws as
this could damage or distort the casing.
7. Ensure that the "Reset" and the "Hard-Wired Siren
tamper detect" jumper links are set in the OFF
position.
8. Connect battery leads to both back-up batteries
and refit batteries.
Battery 1 (left):
Red lead to
+
ve battery terminal
Blue lead to
–
ve battery terminal
Battery 2 (right): Blue lead to
+
ve battery terminal
Black lead to
–
ve battery terminal
IMPORTANT: Take care when connecting battery
leads to the batteries as connecting incorrectly
could damage the batteries or the Control Panel.
Note: The Power LED may flash to indicate that the
unit is being operated from the back-up batteries
and that mains supply is not present.
9. Close the lid of the Control Panel and tighten the
captive fixing screws.
10. Plug in and switch ON the Power Supply Unit, (the
Power LED should illuminate).
11. If required, connect the Control Panel to the
telephone line using the cable supplied by
inserting small RJ11 plug into socket marked LINE
located on the bottom edge of the Control Panel.
TAM
PGND
B+
GND
N.C.
C
N.O.
GND
V+
OUT
GND
Upper Keyhole
Fixing Hole
-ve Terminal
(Black Lead)
+ve Terminal
(Blue Lead)
Reset Jumper
Link P1
Power Supply
Jack Socket
Upper Keyhole
Fixing Hole
+ve Terminal
(Red Lead)
-ve Terminal
(Blue Lead)
Lower Fixing
Hole
External Tamper
Switch Jumper
Link P51
Power Supply
Cable Access
Hole
Inside View of Control Panel