85
Note: If RF Level Offset is enabled, the Mon Port label is cyan-colored indicating that RX measurements
are adjusted by the Mon Port-specific offset. See section
2.2.6.3
Tracking Generator mode
The optional Tracking Generator function sets up the R8100 RF generator in a sweeping mode for
simultaneous use with the spectrum analyzer display. This delivers a valuable capability for measuring
and servicing a wide variety of RF filtering and combining networks. Pressing the Tracking Generator
key provides the full screen display shown in Figure 2.2.6.3-1.
Note: Enabling the Tracking Generator
suspends the Standard zone operation of the R8100 (e.g. RF Zone, Audio Zone, etc.). To restore Standard
zone operation, press the appropriate mode key such as Monitor, Generate, Duplex, etc.
Figure 2.2.6.3-1 Tracking Generator mode
The Tracking Generator settings are similar to those used when operating the RF Generator and Spectrum
Analyzer independently. An exception is the frequency setting which is common to both, since the
Spectrum analyzer is lock stepped to and tracks the swept RF Generator.
Get pic of a filter
Содержание R8100 SERIES
Страница 19: ...19 Figure 2 1 2 Left and Right Sides of the R8100...
Страница 164: ...164 Figure 2 2 7 7 5 Power Profile Frame with Markers...
Страница 224: ...224 Figure 3 2 9 6 1 Submenu after pressing Options soft key in the Settings menu...
Страница 243: ...243 PTC Test in Monitor Mode Eye Diagram Display...
Страница 244: ...244 Power Profile Display Linear and Circular Constellation Displays...
Страница 245: ...245 Symbol Distribution Plot...