WACN ID (P25 Trunk submenu)
Set the Wide Area Communication Network IDentity (WACN ID) of the P25 system being tested. The
range of values is from hexadecimal 00000 to FFFFF. Alpha numeric entries are made using the ▲▼
(Up/Down), and ◄► (Left/Right) keys, numeric keypad, and spin knob.
SYSTEM ID (P25 Trunk submenu)
Set the System IDentity within the WACN of the P25 system being tested. The range of values is from
hexadecimal 000 to FFF. Alpha numeric entries are made using the ▲▼ (Up/Down), and ◄►
(Left/Right) keys, numeric keypad, and spin knob.
WUID (P25 Trunk submenu)
Set the Working Unit IDentity (e.g. ID in the system). The range of values is from hexadecimal 000000
to FFFFFF. Alpha numeric entries are made using the ▲▼ (Up/Down), and ◄► (Left/Right) keys,
numeric keypad, and spin knob.
RFSS ID
Set the RF Subsystem ID of the core infrastructure providing P25 service within the Wide Area
Communication Network. The range of values is from hexadecimal 00 to FF. Alpha numeric entries are
made using the ▲▼ (Up/Down), and ◄► (Left/Right) keys, numeric keypad, and spin knob.
WGID
Set the Working Group IDentity (e.g. talkgroup of the channel). The range of values is from hexadecimal
0000 to FFFF. Alpha numeric entries are made using the ▲▼ (Up/Down), and ◄► (Left/Right) keys,
numeric keypad, and spin knob.
SITE ID
Set the identity of the site within the RF Subsystem. The range of values is from hexadecimal 00 to FF.
Alpha numeric entries are made using the ▲▼ (Up/Down), and ◄► (Left/Right) keys, numeric keypad,
and spin knob.
Band Plan Table
Activates a submenu with a table that defines the channel characteristics for the P25 frequency band from
the perspective of the radio. All of the fields are used to create the Identifier Update
(IDEN_UP/IDEN_UP_VU) TSBK for transmit to the radio; some are used by the R8100 to emulate the
base station. The default plan can be customized with soft keys as described below. See Figure 3.2.8.5-4.
Note: If necessary, use RSS to read system values from the radio.
Содержание R8100 SERIES
Страница 19: ...19 Figure 2 1 2 Left and Right Sides of the R8100...
Страница 164: ...164 Figure 2 2 7 7 5 Power Profile Frame with Markers...
Страница 224: ...224 Figure 3 2 9 6 1 Submenu after pressing Options soft key in the Settings menu...
Страница 243: ...243 PTC Test in Monitor Mode Eye Diagram Display...
Страница 244: ...244 Power Profile Display Linear and Circular Constellation Displays...
Страница 245: ...245 Symbol Distribution Plot...