D – Duplex
00 = Half-duplex, the subscriber unit will be capable of transmitting but not simultaneously receiving on
the assigned channel
20 = Full duplex, the subscriber unit is capable of transmitting and receiving simultaneously on the
assigned channel
M – Mode: data mode of service
00 = Circuit mode, the resources shall support circuit switch operation
10 = Packet mode, the resources shall support packet switch operation
R – Reserved
0 = Set by the sender and ignored by the receiver.
P-L – Priority Level
0 – 7 = The relative importance attribute to the service that is being requested
.
S – Explicit Source ID (Voice Frame Encoder submenu)
Sets Explicit mode for the Source Address in the opcode. When set to “0- Not Required” the Source ID
address is sufficient to completely represent the requesting unit on the current P25 system. When set to
“1 – Required” the next Link Control message will have a Source ID extension carrying the complete
SUID of the requesting unit. Select in a list entry window using the Up/Down (▲▼) keys or spin knob.
Source Address (Voice Frame Encoder submenu)
Enter the Source ID address of the requesting unit. The range of values is from hexadecimal 000000 to
FFFFFF. Alpha numeric entries are made using the ▲▼ (Up/Down), and ◄► (Left/Right) keys,
numeric keypad, and spin knob.
Reset to Defaults (Voice Frame Encoder submenu)
Resets all Voice Frame data fields to factory defaults.
Содержание R8100 SERIES
Страница 19: ...19 Figure 2 1 2 Left and Right Sides of the R8100...
Страница 164: ...164 Figure 2 2 7 7 5 Power Profile Frame with Markers...
Страница 224: ...224 Figure 3 2 9 6 1 Submenu after pressing Options soft key in the Settings menu...
Страница 243: ...243 PTC Test in Monitor Mode Eye Diagram Display...
Страница 244: ...244 Power Profile Display Linear and Circular Constellation Displays...
Страница 245: ...245 Symbol Distribution Plot...