15
Shipping
Remove battery from unit before shipment. See shipping requirements of your carrier.
See “Technical Specifications” for more details about the battery
The maximum input levels are:
70 VAC RMS /100 VDC (R8100 input impedance set to 1 MΩ).
15 VAC RMS /24 VDC (R8100 input impedance set to 600 Ω).
1.3.4
Maximum Meter In Voltages
WARNING
To ensure the safety of the user the Meter In port should not be used to measure equipment
containing mains voltages.
The maximum input levels are:
33 VAC RMS /70 VDC (R8100 input impedance set to 1 MΩ).
15 VAC RMS /24 VDC (R8100 input impedance set to 600 Ω).
1.3.5
Replacement Fuses
There are no user serviceable fuses on the R8100. The unit is internally protected against overloads and
risk of fire. If the R8100 fails to operate return it to the factory or an authorized repair center for diagnosis
and repair.
The R8100 Generate Output Port provides port protection against RF power input up to 5 W continuous.
Power levels above 5 W may damage the port if applied for a significant amount of time. If the operator
desires further port protection the 50RF-038 fuse may be obtained from JFW Industries and attached to
the Generate Output Port.
1.3.6
Other Cautions
Other cautions relating to the operation of the Analyzer are stated in
Italics
throughout this manual.
CAUTION – HOT SURFACES
The RF I/O Port connector may become hot when inputting power. Exercise caution when removing
cabling from the RF I/O Port.
1.3.7
User Maintenance of exterior surfaces
Clean only with a damp cloth and a mild detergent. Do not use abrasives, solvents or alcohol. If the
Analyzer is used in a relatively dust free environment, no other periodic maintenance should be required.
Содержание R8100 SERIES
Страница 19: ...19 Figure 2 1 2 Left and Right Sides of the R8100...
Страница 164: ...164 Figure 2 2 7 7 5 Power Profile Frame with Markers...
Страница 224: ...224 Figure 3 2 9 6 1 Submenu after pressing Options soft key in the Settings menu...
Страница 243: ...243 PTC Test in Monitor Mode Eye Diagram Display...
Страница 244: ...244 Power Profile Display Linear and Circular Constellation Displays...
Страница 245: ...245 Symbol Distribution Plot...