Note: See the Technical Specification: ETSI TS 102 361-1 Electromagnetic compatibility and Radio
spectrum Matters (ERM); Digital Mobile Radio (DMR) Systems; Part 1: "DMR Air Interface (AI)
protocol", Burst timing.
Select View (Power Profile submenu)
Select the slot(s) to view. Although slots are alternating 30 milliseconds, the profile for a slot is 30.5 ms,
divided into three regions for ramp-up (1.5 ms), burst (27.5 ms), and ramp-down (1.5 ms).
Current – Horizontal axis -0.25 ms to 30.25 ms with slot from 0 to 30 ms.
Alternate – Horizontal axis 29.75 ms to 60.25 ms with slot from 30 to 60 ms.
Both – Horizontal axis -0.25 ms to 60.25 ms with slots from 0 to 30 and 30 to 60 ms. See
Note: Ramp up/down times for a slot overlap the adjacent slots by 0.25 milliseconds.
Vertical Maximum (Power Profile submenu)
Adjusts the maximum level for the vertical scale of the display (top line) from -120 dBm to +60 dBm in
1 dB increments.
Vertical Scale (Power Profile submenu)
Selects the vertical scale resolution for the display’s major grid lines from 1 dB/div to 10 dB/div via a
horizontal soft key list.
Display Mode (Power Profile submenu)
Selects the display presentation with the following horizontal menu choices:
Normal – The display updates continuously.
Freeze – Provides a snapshot of the current display indication and stops additional updates.
Max Hold – The display retains the highest peak signal amplitudes measured during successive sweeps.
Average – The displayed signal amplitudes are a rolling average of the peak amplitudes measured on each
successive sweep. The average consists of 1 to 5 sweeps, shown beside the mode indication. See
Marker Mode (Power Profile submenu)
Provides display marker control via a horizontal soft key menu. Markers can be turned off or on with a
choice of numeric readout for the signal measurements. “Absolute” provides actual peak readings while
“Delta” measures the relative difference of both power and time between the markers. See
Toggle Marker (Power Profile submenu)
Cycles through the available markers to select the active one (yellow) for positional adjustment on the
display. The active marker is moved using the Left/Right (◄►) cursor control buttons.
Содержание R8100 SERIES
Страница 19: ...19 Figure 2 1 2 Left and Right Sides of the R8100...
Страница 164: ...164 Figure 2 2 7 7 5 Power Profile Frame with Markers...
Страница 224: ...224 Figure 3 2 9 6 1 Submenu after pressing Options soft key in the Settings menu...
Страница 243: ...243 PTC Test in Monitor Mode Eye Diagram Display...
Страница 244: ...244 Power Profile Display Linear and Circular Constellation Displays...
Страница 245: ...245 Symbol Distribution Plot...