39
ENGLISH
Except when no fold is required, the display shows a simple diagram of the document with
the fold positions. To change the fold positions press
next to a fold. Enter the
required position of the relevant fold.
The next table shows possible fold positions:
Note
The display will indicate when entered positions are out of range.
3.9.5
Optical Mark Recognition Settings (Option)
For a full function description of Optical Mark
Recognition (OMR), see 4.2 ”Optical Mark
Recognition (OMR)” on page 48. Flex-OMR is also
optional. Flex-OMR can read customer specific
codes.
In the “OMR settings” menu it is possible to enable
or disable the OMR function and to adjust the basic
settings for OMR.
The first “OMR settings” menu covers the following
settings:
•
Code type: default is the setting “none”: OMR is
disabled.
Change the setting using the
button. The following codes are possible:
-
1-track OMR
-
2-track OMR (only OMR level 5)
Fold type
Minimum position
Maximum position
Single fold
75 mm (2.95")
25 mm (0.98") (extended
Folder)
Longest document length
minus 25 mm (0.98")
Letter fold
First fold
75 mm (2.95")
25 mm (0.98") (extended
Folder)
Longest document length
minus 50 mm (1.97")
Second fold
Position first fold plus
25 mm (0.98")
Longest document length
minus 25 mm (0.98")
Zig-zag fold
First fold
75 mm (2.95")
25 mm (0.98") (extended
Folder)
Longest document length
minus 100 mm (3.94")
Second fold
Position first fold plus
25 mm (0.98")
Longest document length
minus 75 mm (2.95")
Double parallel
fold
First fold
75 mm (2.95")
25 mm (0.98") (extended
Folder)
Longest document length
minus 50 mm (1.97")
Second fold
Position first fold plus
25 mm (0.98")
Longest document length
minus 25 mm (0.98")