MyCrown Mill
4.4.
Replacing the milling chamber lighting
1. Open the milling chamber door.
2. Pull out the tank.
3. Unscrew the front cover.
4. Unscrew the key mount (5 screws).
5. Use a small screwdriver to pry out the milling chamber lighting PC
board on both sides.
6. Pull off connector X1.
7. Plug connector X1 into the new PC board.
8. Insert the new PC board on both sides until it locks into place.
9. Fasten the key mount tight using the 5 screws you removed earlier.
10. Screw on the front cover.
11. Reinsert the tank.
12. Close the milling chamber door.
X1
Содержание MyCrown Mill
Страница 1: ...j j p j b Service Manual...
Страница 15: ...15 Service Manual b Example Total test Total test...
Страница 33: ...33 Service Manual b 3 1 Force measurement errors...
Страница 34: ...34 MyCrown Mill 3 2 Stepping motor does not move...
Страница 35: ...35 Service Manual b 3 3 Spindle motor does not lock...
Страница 36: ...36 MyCrown Mill 3 4 Milling chamber door switch...
Страница 37: ...37 Service Manual b 3 5 Unit switches off Continued on next page...
Страница 38: ...38 MyCrown Mill Continued from previous page...
Страница 39: ...39 Service Manual b 3 6 Edges break off holes or wide stripes in restoration Continued on next page...
Страница 40: ...40 MyCrown Mill Continued from previous page...
Страница 41: ...41 Service Manual b 3 7 Insufficient air pressure...
Страница 42: ...42 MyCrown Mill 3 8 Stepping motor cannot be controlled...
Страница 43: ...43 Service Manual b 3 9 Faulty water pressure...
Страница 44: ...44 MyCrown Mill Continued from previous page...
Страница 45: ...45 Service Manual b 3 10 Unit cannot find starting position...
Страница 46: ...46 MyCrown Mill 3 11 Unit cannot be turned on...
Страница 47: ...47 Service Manual b 3 12 Touch errors...
Страница 48: ...48 MyCrown Mill 3 13 Service life of the milling and grinding machine is too short...
Страница 49: ...49 Service Manual b 3 14 Milling unit not addressable...
Страница 50: ...50 MyCrown Mill 3 15 LAN communication problems Continued on next page...
Страница 51: ...51 Service Manual b Continued from previous page...
Страница 52: ...52 MyCrown Mill 3 16 WLAN connection occasionally interrupted...
Страница 53: ...53 Service Manual b 3 17 WLAN communication problems...
Страница 67: ...67 Service Manual b 4 5 Replacing stepping motors Overview of stepping motors...