Replacing the (DC) spindle motors
4.2.1
DC motor, single
4.2.1.1
Removal
Preparation
1. Switch the milling unit on.
The motors move into the home position.
2. Switch the milling unit off at the main switch (0).
3. Open the milling chamber door.
Removing the motor unit
1. Remove the fastening screws of the mount cover.
2. Remove the fastening screws of the shaft.
3. Pull the motor mount together with the motor off of the shaft and the
mount cover. At the same time, unplug the power supply connectors.
Removing the motor
1. Remove the fastening screws of the motor.
2. Pull the motor out of the motor mount.
3. If necessary, pull the plug connector strip out of the motor socket and
connect it to the socket in the milling unit.
A
Mount cover
D
Fastening screws, motor
mount/mount cover
B
Motor mount
E
Fastening screws, shaft
C
Fastening screws, motor
E
D
C
B
A
Содержание MyCrown Mill
Страница 1: ...j j p j b Service Manual...
Страница 15: ...15 Service Manual b Example Total test Total test...
Страница 33: ...33 Service Manual b 3 1 Force measurement errors...
Страница 34: ...34 MyCrown Mill 3 2 Stepping motor does not move...
Страница 35: ...35 Service Manual b 3 3 Spindle motor does not lock...
Страница 36: ...36 MyCrown Mill 3 4 Milling chamber door switch...
Страница 37: ...37 Service Manual b 3 5 Unit switches off Continued on next page...
Страница 38: ...38 MyCrown Mill Continued from previous page...
Страница 39: ...39 Service Manual b 3 6 Edges break off holes or wide stripes in restoration Continued on next page...
Страница 40: ...40 MyCrown Mill Continued from previous page...
Страница 41: ...41 Service Manual b 3 7 Insufficient air pressure...
Страница 42: ...42 MyCrown Mill 3 8 Stepping motor cannot be controlled...
Страница 43: ...43 Service Manual b 3 9 Faulty water pressure...
Страница 44: ...44 MyCrown Mill Continued from previous page...
Страница 45: ...45 Service Manual b 3 10 Unit cannot find starting position...
Страница 46: ...46 MyCrown Mill 3 11 Unit cannot be turned on...
Страница 47: ...47 Service Manual b 3 12 Touch errors...
Страница 48: ...48 MyCrown Mill 3 13 Service life of the milling and grinding machine is too short...
Страница 49: ...49 Service Manual b 3 14 Milling unit not addressable...
Страница 50: ...50 MyCrown Mill 3 15 LAN communication problems Continued on next page...
Страница 51: ...51 Service Manual b Continued from previous page...
Страница 52: ...52 MyCrown Mill 3 16 WLAN connection occasionally interrupted...
Страница 53: ...53 Service Manual b 3 17 WLAN communication problems...
Страница 67: ...67 Service Manual b 4 5 Replacing stepping motors Overview of stepping motors...