background image

9

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.

This heater has a pilot which must be lit by hand. When
lighting the pilot, follow these instructions exactly.

B.

BEFORE OPERATING smell all around the heater area for gas.
Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not use any phone in

your building.

• Immediately call your gas supplier from a neighbor’s phone. 
Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

C.

Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand, do
not try to repair it, call a qualified service technician. Forced or
attempted repair may result in a fire or explosion.

D.

Do not use this heater if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.

23.0 LIGHTING INSTRUCTIONS

1. Stop! Read the safety information above.

2. Make sure manual shut-off valve is fully open.

3. Open the glass facia.

4. Depress control knob in and turn clockwise                     to the
“OFF” position ( Figure 7 ).

5. Wait 5 minutes to clear out any gas. Then smell for gas, including near
the floor. If you smell gas, STOP! Follow the safety instructions in “What
to do if you smell gas” under section ‘B’ above. If you do not smell gas,
go to next step.

6. The pilot is located on the left side behind the burner (Figure 8).

7. Depress control knob in and turn counterclockwise
to the “SPARK” position ( Figure 7 ) and hold there for a few seconds.

Note: If you are running the heater for the first time or after an extended
period of non use it will be necessary to press the control knob all the
way in for 30 seconds to allow air to bleed out of the gas piping.

8. Continue turning counterclockwise                        through the spark
click to the PILOT light position, ensuring the pilot has lit. If not, turn the
knob fully clockwise, and repeat.

9. Hold the control knob in for a further 10 seconds to prevent the flame
failure detector from shutting off the gas while the probe is warming up.

10. Release the control knob while turning counterclockwise
to the preferred setting. Close  the control access panel.

• If the knob does not pop out when released, stop and immediately call
your service technician or gas supplier.

• If the pilot will not stay lit after several tries, depress and turn the gas
control knob clockwise                      to “OFF”and wait 30 seconds.
Depress and turn knob counterclockwise                       to “SPARK” and
ignite the heater again. If your pilot does not relight depress and turn
control knob clockwise                      to “OFF” and call your service
technician or gas supplier.

11. Wait 30 seconds before readjusting the heater when the control knob
has been turned down to a lower setting.

24.0 TO TURN OFF GAS TO APPLIANCE

2. Depress and turn control knob clockwise                      to the “OFF”
position (Figure 7). Close  the control access panel.

1. Open the control access panel.

Figure 7 : Control knob. This is located
behind the glass facia panel of the appliance.

Figure 8:Pilot unit. This is located behind the
burner, on the left-hand side of the appliance.

Figure 8

Figure 7

Содержание RADIUM F500080

Страница 1: ...ppliance WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIE...

Страница 2: ...ional as it may not be operating correctly Section Contents Page No 1 0 General Information 2 2 0 Inventory 2 3 0 Appliance Data 2 4 0 Important Safety Information 2 5 0 Codes 3 6 0 Combustion and Ven...

Страница 3: ...ed from The American National Standards Institute Inc 1430 Broadway New York NY 10018 or National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 Seller of unvented propane or natura...

Страница 4: ...s a combustible material or surface Clearance to the sides of the appliance are 4 but curtains drapes and other fabrics are not permitted within a distance of 20 of the appliance sides No such materia...

Страница 5: ...plate The bottom of the heater may be secured onto the lower mounting studs using the wingnuts or the hex nuts provided Mark the positions shown as Radium attachment points on the wall If the applianc...

Страница 6: ...or partially blocked clean out the ports The heater regulator controls the burner pressure which should be checked at the pressure test points located on the control valve itself shown in figure 5 for...

Страница 7: ...it strip off the burner pipes and clean thoroughly 8 Clean the in line restrictor pilot assembly and the burner tube Do not attempt to remove the pilot injector as this can cause damage 9 Re assemble...

Страница 8: ...ons and run at maximum setting for 15 minutes Position gas sample probe directly over a cata lyst via the outlet grille on top of the appliance Record the carbon diox ide CO2 concentration and then th...

Страница 9: ...nder section B above If you do not smell gas go to next step 6 The pilot is located on the left side behind the burner Figure 8 7 Depress control knob in and turn counterclockwise to the SPARK positio...

Страница 10: ...en fire is on high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipework or valve Check all isolators are adequately sized and fully open Check m...

Страница 11: ...G FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS HEATER MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY As our policy is...

Страница 12: ...ALACI N AJUSTE MODIFICACI N REVISI N O MANTENIMIENTO INADECUADOS PUEDEN CAUSAR LESIONES O DA OS MATERIALES CONSULTE ESTE MANUAL SI NECESITA AYUDA O INFORMACI N ADICIONAL CONSULTE A UN INSTALADOR CALIF...

Страница 13: ...gina N 1 0 Informaci n general 13 2 0 Inventario 13 3 0 Especificaciones del aparato 13 4 0 Informaci n de seguridad importante 13 5 0 Normativa 14 6 0 Aire de combusti n y ventilaci n 14 7 0 Requisit...

Страница 14: ...Fuel Gas Code ANSI Z223 1 o NFPA54 que pueden obtenerse en The American National Standards Institute Inc 1430 Broadway New York NY 10018 o National Fire Protection Association Inc Batterymarch Park Qu...

Страница 15: ...ier material susceptible de decolorarse derretirse o deformarse al estar expuesto a un calor moderado debe considerarse como material o superficie combustible Debe dejarse un espacio libre de 4 en los...

Страница 16: ...er sometida a pruebas de estanqueidad antes de aplicar protecci n y o empotrar las tuber as y acoplamientos Una vez que haya seleccionado la posici n final de montaje del aparato teniendo en cuenta lo...

Страница 17: ...be comprobarse en los puntos de prueba de presi n ubicados en la v lvula de control en s ilustrado en la Figura 5 para ajustar la presi n del quemador colector y el regulador La v lvula se encue ntra...

Страница 18: ...del quemador desmonte los tubos del quemador y limpie a fondo 8 Limpie el restrictor en l nea el conjunto del piloto y el tubo del quemador No intente retirar el inyector del piloto puesto que podr a...

Страница 19: ...te al fabricante del equipo Encienda la chimenea siguiendo las instrucciones de uso y deje que funcione durante 15 minutos Ponga la sonda del analizador de gas directamente encima de un catalizador a...

Страница 20: ...n deseada Cierre el panel de acceso a la perilla de control Si la perilla no sale desista y llame inmediatamente a su t cnico de mantenimiento o a su compa a de gas Si despu s de varios intentos el p...

Страница 21: ...I DOBLE EL TERMOPAR PARA HACER QUE EL PILOTO SE MANTENGA ENCENDIDO La llama del piloto se reduce cuando Flujo defectuoso de gas al calentador compruebe la presi n con el calentador en Alto el calentad...

Страница 22: ...VERTENCIA EL NO UBICAR LAS PIEZAS EN LOS LUGARES SE ALADOS EN ESTOS DIAGRAMAS O LA UTILIZACI N DE PIEZAS NO HOMOLOGADAS OFICIALMENTE PARA EL USO CON ESTE CALENTADOR PUEDEN CAUSAR DA OS MATERIALES O LE...

Отзывы: